Product Description

Automatic Vacuum Chamber Helium Leak Testing Equipment for Automotive AC Compressor

 

The automatic helium leak vacuum chamber detection system is suitable for automotive air-conditioning compressor air-tightness testing, but also suitable for testing the sealing performance of the refrigerators, air-conditioning's compressors, to avoid the leakage of hazardous materials.This test system is available for manufacturer's mass production detection applicated in production line.

 

Working Principle:

According to the basic principle of helium leak detection, with helium as the tracer gas, helium is filled into the workpiece in the vacuum chamber, and then the helium leak detector can accurately and quickly judge the leakage of the workpiece.

 

Feature:

Operator connects and seals the return air inlet and exhaust vent of the workpiece by jig, then loads workpiece into vacuum chamber, and then connects the joint of the fixture with the fast joint inside the vacuum chamber. After the vacuum chamber door is closed, system will complete whole process of gross leak and strength test, vacuum, helium filling, fine leak test and helium recovery. The test cycle is fast, and leak detection accuracy is high.

 

Technical Parameters:

Workpiece Automotive air conditioning compressor
Workpiece Dimension L*W*H=215mm*1211.7mm*155.2mm
Workpiece Inner Volume 0.7L
Workpiece Air Inlet Parameters 2pcs; return air inlet diameter 18.3, exhaust vent diameter15.480-0.05mm
Vacuum Chamber 2
Tracer Gas Helium
Gas Pressure for Fine Leak Test 1.5 Mpa (Downward adjustable)
Gas Pressure for Gross Leak Test 2.5 Mpa (Downward adjustable)
Helium Leak Detection Rate 2g/y
Test Cycle 2 vacuum chambers work interlinked, one workpiece is finished in average 30s (including loading and unloading time)
Workpiece Fixture 4 SET
Loading & Unloading Manual
Helium Recovery Yes, recovery rate≥98%

 

Operation Process Chart:

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou HongCe Equipment Co., Ltd.
Location No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
Contact Person Tessa

Request A Quote

Please check your email address.
Your message must be at least 20 characters.