Dongguan Gaoxin Testing Equipment Co., Ltd.,
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

8 Channel Battery Analyzer ( 0.0005A-0.1A, Up to 5V) 5V6A Battery Testing System

Price Negotiable
Price: negotiation
MOQ: 1set
Delivery Time: 10 working days
Brand: Gaoxin
Product Description

BTS-5V6A Battery Testing Equipment (Double Range)

 

Equipment Model : 5V6A Battery Testing System Equipment Item Code:CT-4008-5V6A-S1

 

Project index

Parameter index

Input Power AC 220V ±10% / 50Hz
resolution AD:16bit;DA:16bit
Input Resistance ≥1MΩ
Input Power 426W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Per Channel Voltage Range Charge:25mV~5V; Discharge:1V-5V
Discharge Min Voltage 10mV
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Current Per Channel Current Range Range 1: 0.0005A-0.1A Range 2: 0.1A~6A
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Power Per Channel Output Power 30W
Stop current Range 1: 0.2mA Range 2: 12mA
Stability ± 0.1% of FS
Time Current Response Time 1ms (0-Full Range)
Step Time Range

≤(365*24 )hour/step,

Time Form Support 00:00:00(h,min:s,ms)

Data Recording Record Condition Min Time:100mS
Min Voltage:10mV
Min Current:Range 1: 0.2mA Range 2: 12mA
Record Frequency 10Hz
Charge Charge Mode

Constant Current Charge,Constant Voltage Charge,

Constant Current and Constant Voltage Charge,Constant Power Charge

End Conditon Voltage,Current,Relative Time,Capacity,-△V
Discharge Discharge Mode CCD,CPD,CRD
End Condition Voltage,Current,Relative Time,Capacity,-△V
Pulse charge CCC,CPC
Discharge CCD,CPD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection
  • Power-down Data Protection
  • Off-line Testing Function
  • Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time
Hardware Protection Additional Anti-reverse Protection Model
Voltage and Current Test Sampling 4-wire connecting
Noise <85dB
Database MySQL Database
A Means of Communication of Upper Machine TCP/IP Protocol
Data Output EXCEL,TXT,Graph
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 3U,480*330*130(mm)

 

Equipment Working Environment

 

Working Temperature Range 0℃~40℃
Storage Temperature Range -10℃~50℃
Working Environment Relative Humidity Range ≤70% RH
Storage Environment Relative Humidity Range ≤80% RH

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Dongguan Gaoxin Testing Equipment Co., Ltd.,
Location No.7, Shengfeng Road 523039, Xinhe Industrial Park, Wanjiang, Dongguan, Guangdong, China
Contact Person Miss.

Request A Quote

Please check your email address.