Dongguan Gaoxin Testing Equipment Co., Ltd.,
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

Battery External Short Circuit Testing Equipment With Current Temperaure Voltage

Price Negotiable
Price: negoatition
MOQ: 1set
Delivery Time: 15 work days
Brand: GAOXIN
Product Description

Working Ambient Temperature 10 ℃ ~ 100 ℃ Battery External Short Circuit Testing Equipment

 

1. Sepecifications

 

Voltage,temperature, current collection External connected multi - channel data acquisition instrument or PLC data collection module, Channels are extended in Nx4 mode
Explosion-proof temperature Range RT + 10~200 ℃
Heat preservation material Efficient compression glass wool or Rigid polyurethane foam cotton
Temperature control accurcey 0.1℃
Temperature uniformity ± 2 ℃
Temperature luctuation ± 0.5 ℃
Explosion inner box size 500*500*500mm,
Short circuit Mode

RT Short circuit

high temperature short circuit

Operating ambient temperature temperature 10℃~100℃, humidity 10~90% no condensation
Power AC 220V± 10%, 50/60Hz, 380V ± 1%
Gas consumption 0.5~0.8MPa
Working voltage AC 220V 50Hz-60Hz
Impact voltage AC 1kv/1.2-50μs(max)1min
Maximum testing voltage 100V~1000V
Dc response time ≤5μs
Maximum short circuit current 500A/1000A
The device interior resistance 80±20mΩ
Action time Response time / release time ≯30ms
Performance characteristic

Cold and voltage ≯66%Us

Cold release voltage ≯30%Us,≮5%Us

Operating Mode The remote control with wire or Remote control within 7 meters without barrier
Explosion-proof case material

Inner case: SUS# 304 stainless steel sheet

Outer case: Cold-roll steel sheet with paint

Cotrol Mode Touch-tone or PLC touch screen full-automatic control

 

 

2.  Description

 

Remote controlling large current and short circuit device is designed by combining various battery short circuit test standard requirements. It conforms to such standards and codes as GB/IEC/EN/UN38.3/UL;  According to the standard requirements, the short circuit device must conforms to the internal resistance range far less than 100mΩ so as to achieve the maximum short circuit current required by the test. 

 

 

3. Corresponding Stardards

 

GB 18287-2013, QB/T 2502-2000, IEC 62133-2012, UN38.3, UL 2054, UL 1642, QC/T 744-2006, QC/T 743-2006, IEC 62281-2004,  GB 8897.4-2002, IEC 60086-4:2000, SNT 1413-2004, SNT 1414.3-2004

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Dongguan Gaoxin Testing Equipment Co., Ltd.,
Location No.7, Shengfeng Road 523039, Xinhe Industrial Park, Wanjiang, Dongguan, Guangdong, China
Contact Person Miss.

Request A Quote

Please check your email address.
Your message must be at least 20 characters.