Heating temperature Atomic Absorption photometer 180 - 900nm Wavelength

Price Negotiable
Price: Negotiable
MOQ: 5pcs
Delivery Time: Received payment,within 10 days of delivery
Brand: Macy
Product Description

Heating temperature Atomic Absorption photometer 180 - 900nm Wavelength
 
Specifications:

Mainframe
Model: AA-1800H
Light Source: ≤6 lamps automatic turret, automatic alignment
Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current: pulsed power supply
Optical System: large 1800 /mm grating ruling, full closed optical system
Wavelength Range: 180nm-900nm                  
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy: ≤0.15nm
Wavelength Repeatability: ±0.1nm
Spectral Bandwidth: 0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability: ≤±0.002A/30 min (Static)      
≤±0.005A/30min (Dynamic)
Absorbance Range: 0-4A
Detector: imported photomultiplier tube 
Flame Analytical System
Burner Head: full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber: polymer explosion-proof spray chamber
Nebulizer: atomizer efficient glass atomizer, can also be customized
Ignition Type: microcomputer control, automatic ignition
Gas Control: automatic gas control system
Detection Limits(Cu): 0.002μg/mL
Precision: RSD≤0.5%
Graphite Furnace Analytical System
Heating Mode: vertical heating
Temperature Control Method: vertical optical temperature monitoring graphite tube wall temperature
Temperature Range: room temperature to 3000℃
The Program: automatic temperature control up to 20 order
Temperature Control: the furnace enriched up to 20 times
Characteristics Volume: 0.5 × 10-12g (Cd)
Detection Limit: 0.4 × 10-12g (Cd)
Precision: RSD≤3%
The Cooling Water: can choose cooling water circulation system
Safety: the graphite tube damage, water flow
air pressure and other alarmtemperature overheating protection
Autosampler Graphite Furnace
Sample Tray: 70 sample cups, 6 reagent cup
Sample Volume: 1-100μl
The Smallest Lincrement: 0.1 μl
The Volume of Sample better than 1%(at the time of 10mL-100mL)
Repeatability Volume
Repeated Sampling Frequency: up to 99 Times
Cleaning and Waste each 500mL
Container Volume

 
 Photos:

 


 
 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Macylab Instruments Inc.
Location A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China
Contact Person Jane

Request A Quote

Please check your email address.
Your message must be at least 20 characters.