KOMEG Technology Ind Co., Limited
                                                                                                           
Verified Supplier
36 Years
Since 1990
Menu

Overseas Installation Large Capacity Walk In Climatic Test Chamber For Cable Industry

Price Negotiable
Price: negotiation
MOQ: 1 units
Delivery Time: 30 working days after received 60% deposit
Brand: KOMEG
Product Description

Overseas installation Large capacity Walk in Climatic Test Chamber for Cable Industry
 
 
1 Application: 
 
climatic chamber is also called climate chamber, is an enclosure used to test the effects of specified environmental conditions on industrial products, electronic devices and components, materials, and biological items.
Such a chamber can be used:
1) As a stand-alone test for environmental effects on test specimens
2) As preparation of test specimens for further physical tests or chemical tests
3) As environmental conditions for conducting testing of specimens
 
 
 
2 Overview
 
An environmental test chamber artificially replicates the conditions under which machinery, materials, devices or components might be exposed. It is also used to accelerate the effects of exposure to the environment, sometimes at conditions not actually expected. These conditions may include:
 
1) Extreme temperatures
2) Sudden and extreme temperature variations
3) Moisture or relative humidity
4) Electrodynamics vibrations
5) Electromagnetic radiation
6) Salt spray
7) Rain
8) Weathering
9) Exposure to sun, causing UV degradation
10) Vacuum
Manufactured samples, specimens, or components are placed inside the chamber and subjected to one or more of these environmental parameters to determine reliability or measure after-effects such as corrosion. In the case of machinery such as internal combustion engines, byproducts such as emissions are monitored.
 
An environmental chamber can be a small room used both to condition test specimens and to conduct the test. It can be a smaller unit that's used for conditioning test items. Also, some chambers are small enough to be placed onto a universal testing machine or other test apparatus.
 
Many chambers are set at a certain set of conditions. Others can be programmed to cycle through specified sequences of conditions.
 
 
 
3 Design
 
As test requirements may be relatively simple or complex, environmental test chambers vary widely in size, ranging from small units designed for placement on bench tops to large walk-in chambers. Test chambers generally have viewports or video feeds to allow for visual inspection of the sample during the test. Reach-in chambers provide an opening that technicians may use to handle test samples. Chambers providing interior visual lighting must take into account the heat generated and compensate accordingly.
 
As with the wide variance in size, a number of user control options are available, ranging from simple analog indicators up to more modern digital readouts with LCD displays. Chambers may be computer programmable, and networked or Web-enabled test chambers are also available.[1]
 
 
 
4 Types of test chambers
 
1) Mechanically cooled test chambers
2) Liquid nitrogen cooled test chambers
3) Modular Walk-in Chambers
 

SPECIFICATIONS  
Model KMHW-
4 6 8 13 17 21
Volume(m³) 9 12.9 16.8 16.8 35.2 43.3
Interior Dimensions W(mm) 2100 3000 3900 3000 3900 4800
H(mm) 2100 2100 2100 2100 2100 2100
D(mm) 2050 2050 2050 4300 4300 4300
Exterior Dimensions W(mm) 3250 4160 5050 5050 5050 5950
H(mm) 2350 2350 2350 2350 2350 2350
D(mm) 2250 2250 2250 2250 4500 4500
Control System Balanced Temperature & Humidity Control System
Temp. range Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40ºC,-30ºC,-20ºC,-10ºC,0ºC
Humidity Range 10%,20%,30%~95%
Temp. constancy ±0.5ºC
Humidity constancy ±2.5%R.H
Temp. uniformity ±2.0ºC
Humidity uniformity ±5.0%R.H
Heat up time +20ºC~+80ºC ,Within 60 min
Pull down time +20ºC~-55ºC -40ºC-20ºC-10ºC ,Within 120 or 90 or 60 min
Interior material Stainless Steel Plate(SUS 304)
Exterior material Baked Painting Steel Or Stainless steel(SUS304)
Insulation material Rigid polyurethane foam
Door size (mm) Single wing:W800*H1800;Double wing:W1600*H1800;
Safety Devices(standard) No fuse breaker, over pressureover heat and over current protection for compressor,
over temperature protection, over load protection for blower, dry heat protection
Standard accessories Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator
Refrigeration system Water Cooled
Semi-hermetic compressor, single stage or cascade refrigeration system
CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel 7-inch LCD Touch panel,Chinese or English display selectable
Operation model Program or fix point running
Memory capacity 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles
Accuracy Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
Input Temp.:pt-100, Humidity:pt-100 or ~5V DCV
Comm.port RS-232 or RS-485 (Softawre is option)
Ambient Temp. +5ºC~+35ºC
Wiring method AC 380±10%50Hz ,3 phase 4 wires +Ground Wires
Note:1. We reserve the right to change specifications without prior notice
2.Customized sizes and configurations available

 

Testing standard: 

● GB-2423.2-2008(IEC68-2-2)Test B: High Temperature Test

● GJB360.8-2009(MIL-STD.202F) High Temperature Life Test

● GJBl50.3-2009(MIL-STD-810D) High Temperature Test

● GJBl50. 4(MIL-STD-810D) Low Temperature Test

● GB2423.3-2008(IEC68-2-3)Test Ca: Constant Heat Test

● GB2423.4-2008(IEC68-2—30) Test Db: Damp Heat Alternative Test

● GJBl50.9-2009(MIL-STD-810D) Damp Heat Test
 
Product pictures
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company KOMEG Technology Ind Co., Limited
Location Building 12, Songshan Lake, Small and Medium-Sized Science and Technology Park, Dongguan City, 523808, Guangdong Province, P.R.China
Contact Person KOMEG

Request A Quote

Please check your email address.
Your message must be at least 20 characters.