GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6
GE Datex-Ohmeda S5 IBP Module Features
-
Dual-Channel IBP Monitoring
Supports up to two invasive blood pressure channels (e.g., ART, CVP, PA), allowing simultaneous measurement of different pressure types. -
High Accuracy and Sensitivity
Provides precise pressure readings with high sensitivity for critical care applications. -
Real-Time Waveform Display
Displays continuous pressure waveforms on the monitor screen for live clinical assessment. -
Customizable Labeling
Pressure channels can be labeled according to clinical need (e.g., ART, CVP, ICP) for easy identification. -
Compatibility with Standard Transducers
Supports a wide range of industry-standard disposable or reusable pressure transducers. -
Zeroing Function
Includes manual zeroing functionality to calibrate the transducer and ensure accurate measurements. -
Integrated with S5 Monitor System
Seamlessly integrates with the GE Datex-Ohmeda S5 monitor, sharing data with central monitoring and record systems. -
Compact and Modular Design
Hot-swappable and modular, allowing easy installation, replacement, or service without shutting down the entire system. -
Pressure Range and Display
Wide measurement range (typically -50 to +300 mmHg) with configurable units and display scaling. -
Alarm and Trend Features
Programmable high/low pressure alarms and long-term trend recording for patient monitoring and analysis. -
Digital Signal Processing
Uses advanced DSP for noise reduction and accurate waveform generation. -
Electrical Isolation for Patient Safety
Designed with high electrical isolation to protect patients and ensure system reliability.
Precautions for Using GE Datex-Ohmeda S5 IBP Module
-
Use Compatible Pressure Transducers
Always use transducers that are approved and compatible with the S5 monitor system to ensure accurate readings. -
Perform Zeroing Before Use
Always zero the pressure transducer with the stopcock open to air and at the level of the measurement site (e.g., heart level) before taking measurements. -
Avoid Air Bubbles in the Line
Ensure the pressure line is free of air bubbles, as they can distort waveforms and lead to inaccurate readings. -
Secure All Connections
Make sure all pressure tubing and electrical connections are tight and secure to prevent leaks or signal loss. -
Label Pressure Channels Correctly
Always label and confirm the correct pressure type (e.g., ART, CVP, PA) for each channel to avoid clinical misinterpretation. -
Monitor for Infection Control
Use sterile techniques when connecting pressure lines to the patient. Replace transducers and tubing according to hospital infection control policy. -
Do Not Touch Electrical Contacts
Avoid touching the electrical connectors on the module or cable ends to prevent contamination or electrostatic damage. -
Check for Module Recognition
After inserting the IBP module into the S5 monitor, verify that the system recognizes the module and displays the correct parameters. -
Avoid Excessive Pressure
Do not apply excessive pressure to the transducer or tubing to prevent equipment damage or patient injury. -
Use Electrical Isolation Equipment if Required
If connecting to other devices, ensure proper electrical isolation to maintain patient safety and avoid ground loops. -
Clean According to Manufacturer Guidelines
Clean and disinfect the module and cables according to GE’s instructions to maintain hygiene and extend equipment life. -
Remove Module Properly
When removing the IBP module, do so gently to avoid damaging the connector pins or internal circuitry. -
Verify Alarms and Limits
Always set and verify alarm limits appropriate to the patient’s condition to ensure timely clinical response.
| Brand | Model | Equipment | Parts |
| GE | DASH 2500 | patient monitor | |
| DASH 3000 | patient monitor | DASH module | |
| DASH 4000 | patient monitor | ||
| DASH 5000 | patient monitor | ||
| Cardiocap5 | patient monitor | ||
| SOLAR8000/I/M | patient monitor | TRAM/SAM module | |
| Ohemda Trusat Trusignal | Pulse Oximeter | ||
| Ohemda Tuffsat | Pulse Oximeter | ||
| Responder 3000 | Defibrillator |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.