M3000-60003 Non-Invasive Blood Pressure (NIBP) Pump NIBP Module For IntelliVue MP2/X2 /MP20 /MP30/ MP50/ MP70
| Part Number | M3000-60003 |
|---|---|
| Alternative OEM Number | 453564748091 |
| Product Type | NIBP Pump Assembly (internal component) |
| Condition | Typically available as refurbished, tested, or OEM surplus |
| Core Exchange | Often required (old unit returned for refurbishment) |
The M3000-60003 NIBP pump is compatible with specific patient monitors and Multi-Measurement Modules (MMS). Compatibility is primarily determined by serial number ranges.
| Device Family | Specific Models / Requirements |
|---|---|
| IntelliVue | MP2 (M8102A), X2 (M8002A), MP5 |
| MMS Modules | M3001A MMS Module with serial numbers starting with DE6 or higher, specifically DE9 |
| Additional Devices | M3002A Module |
The NIBP module is the pneumatic heart of the blood pressure measurement system. It performs the following functions:
- Cuff Inflation: The internal pump generates the necessary pressure to inflate the blood pressure cuff wrapped around the patient's arm or leg.
- Controlled Deflation: Precision valves manage the gradual release of cuff pressure according to the oscillometric measurement principle.
- Pressure Transduction: The assembly contains sensors that detect pressure oscillations in the artery, which are then converted into electrical signals for processing by the monitor's main system.
The M3000-60003 is an internal component that resides within the M3001A MMS module or the monitor chassis. Replacement requires disassembly of the device. For the MP5 monitor, replacement involves a multi-step process including:
- Removing the power supply
- Removing system interface and recorder boards
- Accessing the NBP pump cage
Common failure indicators that suggest NIBP pump replacement include:
- "NIBP Hardware Error" messages
- "Pump Timeout" or "Leak Test Failed" alarms
- Failure to inflate or maintain cuff pressure
- Inaccurate or erratic blood pressure readings despite proper cuff placement
- Unusual noises from the pump (grinding, continuous running)
After replacing the M3000-60003, the following steps are typically required:
- NIBP Calibration: A full static pressure calibration must be performed to ensure clinical accuracy
- Leak Testing: Verification of pneumatic system integrity
- Service Mode Access: Calibration procedures are performed through the monitor's internal Service Mode (requires specific access key sequence or password)