50Hz 120kw water-cooled 200v Gas Generator Set with 4-stroke water cooling Engine
50Hz 120kw water-cooled 200v Gas Generator Set with 4-stroke water cooling Engine
Genset working condition:
Altitude: 500m above sea level
Ambient temperature: 0ºC ~ + 40ºC (The temperature lower than 0ºC will need oil heater and water heater)
Required Gas Pressure: 7-12kPA
Biogas Requirement: CH4 content≥55%, Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ).
If use low heat value gas for fuel Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas does not include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤100mg/Nm3
NH3 content≤20mg/Nm3na
Impurities content≤30mg/Nm3;size≤5μm
Water content≤40g/Nm3, no free water.
Scope of Supply:
| Serial No. | Name | Specification | Qty | Note | |
| 1 | Generator set (Standard) | ||||
| 1.1 | Engine | HGN14 | 1 | Natural Aspiration | |
| 1.2 | Alternator | LSA44.3L10 | 1 | 400V, 3ph, 4wire, 0.8 lagging | |
| 1.3 | Mixer | Manual | 1 | Manually regulate the A/F ratio | |
| 1.4 | Controller | DSE7320 | 1 | Islands operation | |
| 1.5 | Radiator | Engine-Drive | 1 | Skid Amounted | |
| 2 | Synchronizing Parallel System with State grid FOR OPTION | ||||
| 2.1 | Controller | IG-NTC-BB |
1 | Control and monitor gas gen-set and regulate AFR ratio automatically according to the actual running situation as well as parallel with state grid | |
| 2.2 | Breaker | Motorized | 1 | ||
| 3 | GAS Train (Standard) | ||||
| 3.1 | Ball valve | Manually Cut off gas pipe | 1 | Required gas pressure is 7-12kPa. Regulate the gas pressure, protect gas gen-set running safely |
|
| 3.2 | Solenoid valve | Automatically Shut off gas pipe | 1 | ||
| 3.3 | Zero Pressure Regulating valve | Regulate the gas pressure | 1 | ||
| 3.4 | Fire arrestor |
Prevent backfire | 1 | ||
| 4 | Remote Radiator Type FOR OPTION | ||||
| 4.1 | Remote Radiator | Radiator and motor | 1 | Driven by motor | |
| 5 | Container System FOR OPTION | ||||
| 5.1 | Silent canopy | 1 | Noise attenuation and Ventilation | ||
| 6 | Gas leaking detector FOR OPTION | ||||
| 6.1 | Gas leaking detector | 1 | Inspect the combustible gas and warn and shutdown gas gen-set | ||
| 7 | Oil top up FOR OPTION | ||||
| 7.1 | Auto oil supplement | 1 | Valve will be opened to auto supply the oil when the oil level is lower than standard | ||
| 7.2 | Oil tank | 1 | Reserve the oil for long time maintenance | ||
| 8 | Oil heater | FOR OPTION | 1 | Preheat oil | |
| 9 | Water heater | FOR OPTION | 1 | Preheat jacket water | |
| 10 | Oil and gas separator | FOR OPTION | 1 | Recycle the crankcase exhaust | |
| 11 | I-LB+ | FOR OPTION | 1 | Local Area Net | |
| 12 | IBNT | FOR OPTION | 1 | Internet Bridge | |
Genset Specification:
| Model | LR120-G |
| Gas Generator Set Parameters | |
| Prime power (KVA/KW) | 120KW |
| Continuous power (KVA/KW) | 100kW |
| Rated voltage(V) | 400 |
| Rated frequency(Hz) | 50 |
| Rated current(A) | 216 |
| Steady-state voltage regulating rate | ≤±1.5% |
| Transient voltage regulating rate | ≤±20% |
| Voltage recovery time(s) | ≤1 |
| Voltage fluctuation rate | ≤1% |
| Voltage waveform distortion rate | ≤5% |
| Steady-state frequency regulating rate | ≤1% (adjustable) |
| Transient frequency regulating rate | -10%~12% |
| Frequency recovery time (s) | ≤7 |
| Insulation class | H |
| Engine parameters | |
| Engine model | HGN14 |
| Type | Inline,4-stroke,water-cooling,Wet cylinder, Electronic controlled high energy ignition, pre-mixed mixture proportion combustion |
| No. of cylinders | 6 |
| Bore X Stroke(mm) | 140 X 152 |
| Displacement(L) | 14 |
| Compress ratio | 11:1 |
| Rated speed(r/min) | 1500 |
| Fuel gas | Biogas |
| Maximum fuel consumption (m3/kW.h) | ≤ 0.6 (according to the heat valve) |
| Idle speed(r/min) | 700 |
| Oil type | 15W-40CD CNG special oil |
| Oil consumption ( g/kW.h) | ≤1.0 |
| Max.exhaust temp.(POPC) | ≤650 |
Specification of Leroy Somer:
| Alternator Details | |
| Brand | Leroy Somer |
| Model | LSA44.3L10 |
| Rated power (KW) | 120 |
| Rated Frequency (HZ) | 50 |
| Rated Voltage (V) | 400 |
| Power factor Lagging | 0.8 |
| Efficiency | 93.1% |
| Connecting Type | 3 phase, 4 wire |
| Voltage Regulation | ± 1 %(adjustable) |
| Insulation Class | H |
| Cooling Method | Wind-cooling, self-heat-rejection |
Genset Controller for Islands model: DSE7320
Genset lifetime and Warranty
12 months or 2000 running hours warranty covering all manufacturing defects (whichever comes first) after arriving destination port, our company provides free easily-damaged parts for the faults caused by the quality of products
or raw material, but exclude the damageable parts of engine due to customer's incorrect man-made operation. After expiration, our company provides spare parts with cost for maintenance forever.