AC 3 Phase 1MW to 50MW Multiple Sets Parallel Natural Gas Generators with 400V / 230V Adjustable
AC Three Phase 1MW to 50MW Multiple Sets Parallel Gas Generator with 400V/230V Adjustable
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas,etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: for natural gas≥85% CH4 ,content:for biogas≥40%
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Gen set output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas does't include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤200mg/NM³
NH3 content≤20mg/NM³
Impurities content≤30mg/NM³;size≤5μm
Water content≤40g/NM³, no free water.
Acceptable working conditions:
Ambient temperature : -10°C~+40°C
(antifreeze or preheater needed for below 0'C)
Relative humidity:<90%(20'C)
Altitude:≤1000m
Normal working conditions:
Gen set can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20'C, Relative Humidity: 30%.
Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body , crank shaft, cam shaft, piston, cylinder head, etc made by US Googol with best quality
2. Brand new brushless France Altercate,Leroy Somer,Stamford alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H (60Hz 1200RPM option)
4. Radiator for 40'C/50'C ambient temperature
5. Ignition system adopted Germany Motortech
6. Emergency stop mounted
7. Battery,Battery cable and Battery charger
8. Standard tool box
9.Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw )
10.Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand)
Accessories list
1. Maintenance Operation manual
2. Quality certificate, Gen-sets ex-factory testing report
Optional:
1. Sound-proof / Container canopy
2. CHP & CCHP system
3. Grid parallel system
4. Remote radiator or horizontal type radiator
5. Auto oil filling system
6. Water heater
7. Oil heater
8. Gas leaking detector
9. Flame detector
10.Gas scrubber
Generator Data:
| Genset Model | LR1250 |
| Continuous Power (kW/kVA) | 1000/1250 |
| Rating Power Factor | 0.8 |
| Rating Voltage | 415/240V |
| Rating Current | 1739 @ 415V, 0.8PF |
| Frequency | 50Hz |
| Speed | 1500rpm |
| Nature Gas Heat Value | Low Value ≥36MJ |
| Gas Engine Model | LE3240G3 |
| Generator Model | LSA50.2M6 Leroy Somer |
| Generaor Control Module | IG-NT Comap |
| Output Breaker Panel | ACB 2500A/3P, ABB |
| Cooling Type | Remote Radiator with Electrical motor |
| Start Mode | Electrical start motor, 24VDC |
| Genset Open Type Size | 5000*1800*2350 mm |
| Genset Weight | 11500kg |
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25'C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Get in Touch