Adjustable Speed 140W 1850rpm DC Parking Lot Barrier Gate with Anti-Collision Protection
Price:
negotiable
MOQ:
Sample order accepted
Delivery Time:
5-10 working days after payment received
Brand:
SINOMATIC
Product Description
Adjustable DC 140W 1850rpm Parking Lot Barrier Gate
DC Parking Lot Barrier Gate / Speed Adjustable Model Parking Entrance Barrier
Technical Specifications
Working Temperature (Motor): -35℃ to +85℃
Rated Voltage: DC24V
Running Speed: 1.5s to 8s
Rated Current: 8.58A
Rated Power: 140W
No-load Speed: 1850rpm
Rated Speed: 1400rpm
Output Power: 56.8N.m
Relative Humidity: ≤90%
Remote Control Distance: ≤100M (open area)
IP Rating: IP44
Maximum Arm Length: 6M
Advanced Safety Features
Anti-Collision Protection
Protects the boom arm from damage when collided by vehicles
Pressure Resistance Bounce Safety
During descent, the boom arm immediately returns to vertical position when obstructed, protecting vehicles and pedestrians. Sensitivity is adjustable.
Product Images
Arm Specifications
| Arm Type | Arm Length | Spring Type | Specification (Diameter*Length) |
|---|---|---|---|
| Straight Arm/Folding Arm | 6M≥L>5M | Extension Spring | (ø5.5x280)+(ø4.5x280) |
| 5M≥L≥4.5M | (ø5.5x280) | ||
| 4.5M>L≥3M | (ø4.5x280) | ||
| Fence Arm | 5M≥L≥4M | (ø6.5x280)+(ø6.5x280) | |
| 4M>L≥3M | (ø5.5x280)+(ø4.5x280) |
Key Features
- Adjustable running speed from 1.5s to 6s
- Quick interchange capability
- Manual operation via motor wheel during power outage with automatic reset after power restoration
- Curved crank arm three-link movement structure for stable operation
- Wireless remote control for open/close functions
- Auto reverse function with adjustable force
- Infrared photocells connector available
- Loop detector connector available
- Seamless integration with car parking systems via wire control (switch signal required)
Speed Adjustment Parameters
| Menu Code | Number | Menu Code Name | Defaults | Unit | Remarks |
|---|---|---|---|---|---|
| H00-00 | 25-95 | Open speed adjustment | 40 | Corresponding PWM duty cycle 25%-95%, step size is 1 | |
| H00-01 | 25-95 | Close speed adjustment | 40 | Corresponding PWM duty cycle 25%-95%, step size is 1 | |
| H00-02 | 5-40 | Open in place decelerate angle | 35 | The larger the angle value, the less likely it is to shake the arm when it is in place | |
| H00-03 | 5-40 | Close in place decelerate angle | 35 | The larger the angle value, the less likely it is to shake the arm when it is in place | |
| H00-04 | 1-20 | Open accelerate adjustment | 10 | ms | The smaller the number, the faster the speed |
| H00-05 | 1-20 | Close accelerate adjustment | 10 | ms | The smaller the number, the faster the speed |
| H00-06 | 1-30 | Open in place angle | 2 | degree | step size is 1 |
| H00-07 | 1-30 | Open in place angle | 1 | degree | step size is 1 |
| H00-08 | 7-13 | Auto reverse force adjustment | 10 | A | step size is 1 |
| H00-09 | 0-90 | Delay closing adjustment | 0 | Sec | step size is 100; 0 is not closing automatically, Other value will be closing automatically; This parameter is for when there is no loop detector signals and non-automatic operation occasions |
| H00-10 | 10-50 | Self-check speed adjustment | 30 | Corresponding PWM duty cycle 10%-50%, step size is 1 | |
| H00-11 | 0-2 | Self-check mode | 0 | 0:no operate automatically; 1:operate automatically,remove after power off; 2:operate automatically,Power failure memory | |
| H00-12 | 0-5 | Self-lock force adjustment(Invalid) | 3 | ||
| H00-13 | 1-20 | Motor deceleration time when paused | 5 | The larger the setting, the longer the pause time will take | |
| H00-14 | 0-1 | The default direction of operation after self-test | 0 | 0:Closing,1:opening | |
| H00-15 | 1-10 | Number of pole pairs(Invalid) | 4 | Only used to correctly display motor speed values | |
| H00-16 | 1-32 | RS485 communication address | 1 | Up to 32 slaves can be connected | |
| H00-17 | 0-2 | RS485 communication rate | 0 | 0:9600,1:19200,2:38400; Change the parameter and will be valid after power on again | |
| H00-18 | 0-1 | If self-test after power is on | 1 | 0:no self-test after power on,1:self-test after power on | |
| H00-19 | 0-3 | Manual self-test adjustment | 2 | 0:Manually invalid,1:Keyboard SET button,2:remote control valid,3,Keyboard SET button and remote control both valid | |
| H00-20 | 0-15 | Monitoring parameter setting index | 7 | 7,operation times(ms):0~9000 8,Cumulative operation times:0`99999999 9,automatically operation times :0~99999999 10,Collision times:0~99999999 11,Closing in place times:0~99999999 12,Power-on time (minutes):0~99999999 13,power-on times:0~99999999 14,Input port status:Binary display 15,Error code:0~7 |
|
| H00-21 | 0-3 | reset | 0 | 1:rest adjustment | |
| H00-22 | 0-1 | LED output mode | 0 | 0:Do not flash alternately during operation; 1:Allow flashing |
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED
Location
3F, Bldg B, No. 55 Langbei Vlg, Tongde Community, Baolong, Longgang, Shenzhen, 518116, China.
Contact Person
Manfrid Lee