Alloy Integral Pilot Solenoid Pulse Jet Valves SCG353A050 Normal Close 2 Inch

Price Negotiable
Price: Negotiation
MOQ: 1 pc
Delivery Time: Negotiation
Brand: BRANDO
Product Description

Normal Close 2" Inch Alloy Integral Pilot Solenoid Pulse Jet Valve SCG353A050

 

The 353 series is a two-position normally closed, internal pilot type two-stage pulse diaphragm valve. The valve body is made of aluminum and has a threaded connection port.,The pipe connection must match the parameters indicated on the product nameplate.

Note

Reducing the diameter of the pipe may cause the solenoid valve to malfunction or malfunction.

To protect the solenoid valve, install the appropriate strainer or filter as close as possible to the inlet end.

 

Used for bag house dust collector

Working pressure:0.4~0.6MPa

Working medium: Compressed clean air

Voltage:DC24V, AC24V, AC110V, AC220V/50HZ

Temperature:-10°C~55°C

The relative humidity of air not exceeding 85%

Service life of diaphragm:1 million times

 

Dimension of Pulse Valve

Type Port Size Orifice(mm) Kv/Cv Pressure
M3/h I/min Mix Max
SCG353A047 1 1/2" 52 46 768 0.35 8.5
SCG353A050 2" 66 77 1290 0.35 8.5
SCG353A051 2 1/2" 66 92 1540 0.35 8.5
SCG353B060 3" 75 170 2833 1 6

 

Other Size of Pulse Jet Valve

Delivery

 

Precautions for use

1. If the raw material tape, paste, lubricant is used when it is fixed. To prevent their particles from entering the system.
2. Use the correct tool and use the installation tool as much as possible at the connection point.
3. To prevent damage to the solenoid valve, do not over-tighten the pipe.
4. Do not use the valve body or coil as a lever.
5. The pipe cannot be connected to any force, bend or deformation after the pipe is connected.
6. If electrical connections are made, they must be performed by trained personnel and must comply with local regulations and standards. All electrical screw terminals must be properly secured to standard before use. Depending on the voltage, electrical components must be grounded and must comply with local codes and standards.

7. Perform an electrical test first before applying pressure to the system. Power on the solenoid valve a few times, pay attention to whether you can hear the metal click that indicates the normal operation of the solenoid valve.
8. Most solenoid valves are equipped with coils that allow them to operate continuously. In order to prevent personal injury or property damage, please do not touch the solenoid valve because it will generate heat under normal working conditions. If the solenoid valve is easily accessible, the installer must provide protection against accidents caused by contact.

 

please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.

 

Welcome our inquiry!

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Brando Hardware Co., Ltd
Location 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Contact Person Brandon Bao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.