1/4'' Inch Golden Yellow Color 2V Water Control Valve 2W025-08 made of Superior Brass

Price Negotiable
Price: negotiation
MOQ: 1 pc
Delivery Time: 7 working days
Brand: OEM
Product Description

1/4'' Inch Golden Yellow Color 2V Water Control Valve 2W025-08 made of Superior Brass

 

About Voltage selection:
1. Standard Voltage: DC24V; 110V AC/50hz, 220V AC/50HZ; 110V AC/60HZ, 220V AC/60HZ
2. Also have DC12V and other voltages. but DC12V power is weak, so fluid pressure is lower than other voltages
Valves' installation:
Fluid flow direction must follow the flow arrow marked on valve body.
Installation: must be horizontal position.
Fluid pressure: working under the valves requirements.
Fluid requirement: clean without impurity.
 
Model No. 2W025-08
Working Medium Air,Water,Oil,Gas
Motion Pattern Direct Drive Type
Type Normal Close Type
Aperture of Flow Rate 2.5
Joint Pipe Bore 1/4”
Operating Temperature Rang -5~80
Voltage Range ±10%
Operation Fluid Viscosity 20 CST(below)
Working Pressure(kgf/cm Gas:0~7, Oil:0~5, Air:0~7, Water:0~5
Material of Oil Seal NBR,EPDM Or Viton

Outlook picture of 2W025-08

Drawings of 2W025-08

Sample of valve body

 

The Electromagnetic Valve Fault and Eliminate:
electromagnetic valve does not work after the power supply:
1, check the power supply wiring whether bad -)

connectors and wiring connection again;
2, check whether the power supply voltage in the plus or minus working range --) to switch to normal position;
3, whether the ring

sealing off -) to welding;
4, coil short circuit, replace the coil;
5, differential pressure is not appropriate to work -) -) or replacement of proportion adjustment pressure

difference electromagnetic valve;
6, fluid temperature is too high -) change of proportion of electromagnetic valve;
7, have impurities to make electromagnetic valve of the

main valve core and the moving core card die -) cleaning, such as seal damage the seal and install the filter should be changed;
8, the liquid viscosity is too large, high

frequency and life expectancy has to -) replacement products.

(2) the solenoid valves can't shut down:
1, the main valve core or moving iron core of seal is damaged, replace the seal;
2, fluid temperature, viscosity is too high -) change

of the electromagnetic valve;
3, have impurities into the solenoid valve core or moving iron core -) for cleaning;
Four, spring life have to or replace the spring deformation
5, orifice balance hole jam --) timely cleaning;
6, working frequency is too high, or life has to -) election products or replacement products.
(3) other situations:
1.internal leakage, check whether the seal is damaged, the spring is bad assembly.
2, outside leakage -) joint looseness or seal has bad -) screw or replace the seal;
3.electricity from time to tome noise -) leader on fasteners loose, tighten. Voltage fluctuation is not allowed within the scope of adjust voltage. Core surface impurities or

uneven absorption, clean or replace in a timely manner

 

Any question will be answered at once,If you have the current or future demand,plz contact us without any hesitation!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Brando Hardware Co., Ltd
Location 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Contact Person Brandon Bao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.