CQC/CE MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply
Price:
43-429 usd
MOQ:
1
Delivery Time:
7-10 working days
Brand:
ESTEL
Product Description
CQC/CE MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply
1. CQC/CE MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply Input Characteristics
| Input voltage range |
85-264Vac/120~370Vdc
|
|
Input voltage frequency
|
47-63 Hz
|
|
input currenton
|
MAX. 0.95A @115 Vac, MAX. 0.56A @230 Vac
|
|
surge current
|
<45A @ 230Vac
|
|
leakage current
|
<0.25mA (RMS)/3.5mA(RMS)
|
2. CQC/CE MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply Output Characteristics
|
MPT50-12V
|
MPT50-24V
|
|
12V
|
24V |
|
10.2~13.8V
|
21.6~28.8V
|
| 4.2A | 2.2A |
|
±0.5%
|
±0.5%
|
| ±0.5% |
±0.5% |
|
≤120mVp-p
|
≤150mVp-p
|
|
≤3s @ 115Vac;≤3s @ 230Vac
|
|
|
≤50ms @ 115Vac;≤50ms @ 230Vac
|
|
|
≥45 ms @ 230Vac
|
|
3. MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply Physical characteristics:
|
Dimension
|
100 X 82X 30.1mm (L * W * H)
|
|
Weight
|
About 222g
|
|
Cooling mode
|
Natural air cooling
|
4. MPT50-12V AC/DC Single-Group Output Industrial Control Flat Power Supply Safety regulation
| Safety standards | IEC/EN62368-1,UL 62368-1,GB4943.1 |
| Shock protection | Class I |
| Class of protection | IP20 |
| Insulation impedance | Input-output :≥100MΩ (measured with DC500V at room temperature) Input - Ground :≥100MΩ (measured with DC500V at room temperature) Output - Ground :≥100MΩ (measured with DC500V at room temperature) |
| Insulation strength | Input-output :AC 3KV 50Hz 1 minute ≤10mA Input - Ground :AC 1.5KV 50Hz 1 minute ≤10mA Output - Ground :AC 0.5KV 50Hz 1 minute ≤10mA |
5. MPT50 Power Supply Payment & Shipping Terms
| Minimum Order Quantity: | 1 set |
| Price: | negotiation |
| Payment Terms: | T/T |
| Supply Ability: | 20,000 sets per month |
| Delivery Time: | 7-10 working days |
| Packaging Details: | carton/wooden case |
6. Products images:
Note :
1. Unless otherwise specified, the above parameters are tested under the conditions of ambient temperature
25℃, humidity 50%, 100% load and input voltage 230Vac;
2. When working above 2000 meters above sea level, the load is derated by 7%/1000 meters;
3. Ripple and noise measurement method: use a twisted pair wire about 10mm long, and the terminal should
be connected in parallel with 0.1uf and 10uf capacitors, and measure under 20MHZ bandwidth;
4. The start time is measured in the cold start state, and rapid and frequent switching may increase the start
time;
5. The power supply should be considered as part of the components in the system. All EMC tests will be
conducted with the test sample mounted on a metal plate with a thickness of 1mm and a length of 300mm by
a width of 300mm. Verify the electromagnetic compatibility of the power supply with the terminal device;
6. When the product terminal is used, the shell must be connected to the system;
7. The test methods of all indicators in this guide are tested according to the company's standards.