40U Anti-Rust Paint Outdoor Equipment Enclosure Climate Controlled Cabinet
40U Anti-Rust Paint Outdoor Equipment Enclosure Climate Controlled Cabinet
Quick Details:
| Place of Origin: Shenzhen, China (Mainland) | External Size H×W×D 1800×1000×1000mm |
|
Brand Name: ESTEL |
Structure: double wall, with insulation, sandwich structure |
|
Model Number: ET100100180 |
Cabinet Layout: one compartment, for installing 19” equipment and managing cable |
|
Product Name: Outdoor Telecom Equipment Cabinet |
Cabinet Lock: anti-theft three point lock |
| Certification: ISO9001, CE, 3C, FCC, TLC, IP55 |
Protection Level: IP55 |
| Application: outdoor telecom base station | Cable Entry: at cabinet bottom |
| Material: galvanized steel | Illumination: DC48V LED lamp |
|
Heat Insulation: PEF |
Grounding Protection: copper bar |
|
Color: grey (support custom made) |
Cooling: AC220V 60HZ air conditioner |
|
Coating: anti-corrosion outdoor powder coating |
Accessories Options: PDU |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 set |
| Price: | negotiation |
| Payment Terms: | L/C,D/A,T/T, Western Union, Paypal, etc |
| Supply Ability: | 8,600 sets per month |
| Delivery Time: | 10-15 working days |
| Packaging Details: | wooden case |
1. Specifications
(1) Technical Parameters
| Item | Type | Technical Parameter |
| Structure | Dimension | External Size H×W×D 1800×1000×1000mm |
| Layout | One compartment | |
| Equipment Installation Method | 19” standard rack | |
| Door |
With one front door and one back door, totally two doors; and anti-theft three point lock for outdoor cabinet (support padlock) |
|
| Material |
1.Galvanized steel; 2.Double wall, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
|
| Structure | Assembled | |
| Ingress Protection | IP55 | |
| Temperature Control | Cooling | AC220V 60HZ 1500W Air Conditioner |
| Lighting | LED lamp | 48V LED lamp |
| Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
| Storage Temperature: -50°C ~ + 70°C | ||
| Transport Temperature: -50°C ~ +70°C | ||
| Humidity | Relative Humidity | 5% ~ 100% |
| Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
| Radiation Intensity | Solar Radiation Intensity | 1124 × (1±5%)W/m2 |
(2)Accessories List
| No. | Item | Quantity | Unit | Specs |
| 1 | Outdoor Telecom Cabinet | 1 | Set |
(1) External Size H×W×D 1800×1000×1000m (2) One compartment, the upper compartment is equipment compartment, the lower compartment is for managing cables. (3) With one front door and one back door, totally two doors; and anti-theft three point lock for outdoor cabinet (support padlock) (4) Material: galvanized steel; double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
| 2 | Air Conditioner | 2 | Set |
Cooling Capacity: 1500W Power Supply: AC220V 60HZ Model: TC06-150JFH/01 One installed on front door and the other one installed on rear door |
| 3 | Power Distribution Unit | 1 | Set |
Grade B Lightning Proof AC Input: 63A/2P *1; AC Output: 16A/1P*4; DC Output: 16A/1P*4. Height: 4U |
| 4 | Door Sensor | 1 | Set | Used for Controlling LED lamp on/off |
| 5 | LED Lamp | 1 | Pc | DC48V |
| 6 | Package | 1 | Set | Wooden Case |
Dimension Diagram
Cabinet External Dimension (W×D×H):1000×1000×1800mm (excluding air conditioner and pole)
2. Application Scope
The ET100100180 Outdoor Base Station Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.
3. Cabinet Introduction
3.1 Cabinet Material
The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF. The cabinet is assembled type.
3.2 Cabinet Structure
The cabinet includes two compartments, with separated upper compartment and lower compartment. The upper compartment is equipment compartment, including 19” rack, 30U space. The lower compartment is for managing cables.
3.3 Cabinet Door and Lock
The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock.
4. Main Electrical Components
LED illumination lamp are on top of the cabinet.
5. Wire Routing Design
5.1 Feeder cable and other external cables all use bottom wiring method.
5.2 Users can put cables from the top of the pole. After going through the pole, cables will enter the cabinet through the bottom cable entrance hole.
6. Grounding Protection
- The cabinet includes grounding copper bar with anti-corrosion coating, with 120mm2 sectional area. There are enough screws for wiring connection terminals.
- The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
- Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.
7. Theft Proof Design
7.1 Door lock theft proof design
- Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
- Three point lock
7.2 Connection and Fastening
- Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
- Door hinges use inner hinge mode.
7.3 Appearance and Surface Treatment
Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.
8. Features
8.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
8.2 The cabinet cooling use two air conditioners, which work in alternation to continuously keep thermostatic inside the cabinet.
8.3 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.
8.4 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
8.5 The cabinet uses assembled structure, easy for installation.
8.6 The cabinet includes 19” standard installation rack.
8.7 The cabinet includes stainless steel pole, for user to installing antenna.
9. Technical Specs
- Applicable environment conditions:
Environment temperature: -40°C ~ + 70°C
Environment humidity (RH): ≤95% (at + 40°C)
Air pressure: 62kPa ~ 102kPa
- Material: quality galvanized steel
- Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
- Cabinet load bearing: ≥600kg
- Ingress protection: IP55
- Flame retardance: comply with GB5169.7 test A
- Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2X104M/500V(DC).
- Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
- Mechanical strength: each surface can bear upright pressure>980N; after the door is open, its outer end can bear upright pressure >200N.
10. Cabinet Installation
10.1 Position of installation hole at cabinet base is as the following diagram.
Diagram 1
10.2 Users prefabricate concrete base.
10.3 Pre-embed 4pcs M10×100 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1, with 40mm bolt exposed height. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench.
10.4 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts.
11. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
12. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.