Electronic & Instrument Enclosures

IP55 Outdoor Cabinet Air Conditioner Active Cooling RS485 Communication Alarm Output

Price Negotiable
Price: 215-1215 usd
MOQ: 1 set
Delivery Time: 15-20 working days
Brand: ESTEL
Product Description

IP55 230VAC 50Hz 300W Outdoor Cabinet Air Conditioner Active Cooling RS485 Communication Alarm Output Dry Contact

 

 

1. Outdoor cabinet air conditioner introduction

 

The air conditioner is one kind of refrigeration product self-developed for cabinet. It is applicable in the place where the cabinet internal heat is very large, the internal electronic equipment is sensitive to the environment temperature and which should be isolated internally and externally completely. This product has multiple functions, high reliability, and has the feature that it can start to work without complex debugging after powering.

 

The fan in the internal cycle air path absorbs the hot air from the upside to make air heat exchange by evaporator fins, and sends the cooled air from the downside of the air conditioner. By so, the air in cabinet can cycle to achieve the purpose of lowering the temperature. Meanwhile, The fan in the external cycle air path absorbs the external cold air from the downside, and discharges the hot air from the upside after heat exchange.

 

 

 

2. Technical parameter

 

Item Name Unit Parameter
Dimension and installation Body outline dimension (height*width*depth ) mm 550*320*169

Outline dimension including

flange(height*width*depth )

mm 582*352*169
Weight Kg 12.5
Installation method Door Mounted
Application environment Outdoor
Environment and protection Working environment temperature -40 to +55
Noise dB(A) 54
IP grade IP55
Refrigerant R134a
ROHS certification yes
Performance Input voltage range 220±15%VAC~50Hz
Refrigerating capacity(L35/L35) W 300
Rated Refrigerating input power(L35/L35) W 235
Rated Refrigerating current (L35/L35) A 1.1
Maximum Refrigerating current A 1.6
Heat capacity(optional) W 300
Air Volume of Inner Circulation m3/h 135
 

 

 

3. Applications

 

The environment of outdoor cabinet is dusty and humid, in order to ensure the clean environment of equipment, it is necessary to use air conditioner to isolate the inside of cabinet from the outside environment. Prevent the entry of foreign matters. At the same time, it can prevent the equipment from being damaged by overheating. Ensure that the equipment has a good operating environment.

 

 

4. Feature

 

(1) Compact structure and small volume
(2) Using famous compressor, because the cabinet air conditioning is generally need to work for a long time, the compressor requirements for air conditioning are very high.
(3) Environmental refrigerant
(4) Low noise
(5) Microcomputer digital display: the cabinet belongs to the unattended type. In order to remotely view the operation status of the equipment and the cabinet temperature, and avoid manually starting the air conditioner on site and setting the temperature point, the air conditioner cabinet has the functions of setting the cabinet temperature, fault code display, low voltage, overheat and over-current fault protection and alarm, etc.

 

5.​ Installation size drawing

 

6.  Electrical installation

 

(1) Power input port

 

 

Item Port Definition
Live L power input cable L
Null N power input cable N
Earth PE Earth line
 
 
(2) Alarm output and signal input port
 
Item Port Definition
+ RS485 communication interface RS485A RS485 communication ports (+)
- RS485 communication interface RS485B RS485 communication ports (-)
The public alarm dry nod (NO) NO It is normally open if no alarm
The public alarm dry nod (COM) COM common port
The public alarm dry nod (NC) NC It is normally close if no alarm
Hydrogen discharge / emergency fan dry contact (NO) (Optional) 1 It is normally open if no output
Hydrogen discharge / emergency fan dry contact COM (Optional) 2 Hydrogen discharge / emergency fan dry contact COM
 

7. Remote monitor

Air conditioner has an RS485 communication interface, supporting MODBUS- RTU communication protocol. The air conditioner communicates with the upper monitor through the RS485 communication interface. Or users can check the air conditioner’s running state by viewing the display screen directly and change its running parameters.

 

8. Display interface

 

9. Air conditioner picture

 

 

 

10. Package

 

Carton + wooden pallet

 

 

 

 

11. Production Process

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ESTEL (GUANGDONG) TECHNOLOGY CO., LTD.
Location 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
Contact Person Fiona Liang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.