Yuyao No. 4 Instrument Factory
                                                                                                           
Verified Supplier
61 Years
Since 1965
Menu

2W Series 1/8” Water Solenoid Valve 24V Automotive Electrically Operated Water Valve

Price Negotiable
Price: USD
MOQ: negotiation
Delivery Time: depend on the order quantity
Brand: ROUND STAR
Product Description

2W series 2-way direct acting normally open water air solenoid valve 1/8" ~ 3/8"

 

Options:

Rc thread, sealing material: EPDM VITON VMQ (-10 ~ 130℃)

digital timer, LED light connector

Es low power energy saving coil ( DN≤4mm 1/8" 1/4" AC 220V 4VA DC24V 4W

DN≥4mm 3/8" AC 220V 5VA DC24V 6W)

 

2W-series direct acting(NO)solenoid valve specification table

(ES coil can match EPDM and VITON, but medium temperature must be ≤80℃)

interface

 

orifice

(mm)

Cv

 

 

 

 

 

 

working pressure(bar)

medium

temp.

 

 

 

sealing

material

coil

insulation

degree

 

 

 

coil power

normal order code

 

min

pressure

max pressure Normal coil codecoil Es coil

plastic seal

Voltage AC220V

Thread:G thread

sealing material:blank:NBR E:EPDM V:VITON

 

air gas

water hotwater

liquid light oil

VA

 

W

 

VA

 

 

W

 

AC

220

V

DC

24

V

AC

220

V

DC

24

V

AC DC brass SS316

1/8

 

1.5 0.06 0 16 16 80 NBR H 22 13 4 4 2W-015-06NK-AC220V 2W-015-06JNK-AC220V
1.5 0.06 0 16 16 130 EPDM H 22 13     2W-015-06NK-E-AC220V 2W-015-06JNK-E-AC220V
1.5 0.06 0 16 16 120 VITON H 22 13     2W-015-06NK-V-AC220V 2W-015-06JNK-V-AC220V
2.0 0.1 0 10 10 80 NBR H 22 13 4 4 2W-020-06NK-AC220 2W-020-06JNK-AC220
2.0 0.1 0 10 10 130 EPDM H 22 13     2W-020-06NK-E-AC220 2W-020-06JNK-E-AC220
2.0 0.1 0 10 10 120 VITON H 22 13     2W-020-06NK-V-AC220 2W-020-06JNK-V-AC220
2.5 0.2 0 6 6 80 NBR H 22 13 4 4 2W-025-06NK-AC220 2W-025-06JNK-AC220
2.5 0.2 0 6 6 130 EPDM H 22 13     2W-025-06NK-E-AC220 2W-025-06JNK-E-AC220
2.5 0.2 0 6 6 120 VITON H 22 13     2W-025-06NK-V-AC220 2W-025-06JNK-V-AC220
3.0 0.25 0 5 5 80 NBR H 22 13 4 4 2W-030-06NK-AC220 2W-030-06JNK-AC220
3.0 0.25 0 5 5 130 EPDM H 22 13     2W-030-06NK-E-AC220 2W-030-06JNK-E-AC220
3.0 0.25 0 5 5 120 VITON H 22 13     2W-030-06NK-V-AC220 2W-030-06JNK-V-AC220
4.0 0.3 0 3 3 80 NBR H 22 13 4 4 2W-040-06NK-AC220 2W-040-06JNK-AC220
4.0 0.3 0 3 3 130 EPDM H 22 13     2W-040-06NK-E-AC220 2W-040-06JNK-E-AC220
4.0 0.3 0 3 3 120 VITON H 22 13     2W-040-06NK-V-AC220 2W-040-06JNK-V-AC220

1/4

 

1.5 0.06 0 16 16 80 NBR H 22 13 4 4 2W-015-08NK-AC220V 2W-015-08JNK-AC220V
1.5 0.06 0 16 16 130 EPDM H 22 13     2W-015-08NK-E-AC220V 2W-015-08JNK-E-AC220V
1.5 0.06 0 16 16 120 VITON H 22 13     2W-015-08NK-V-AC220V 2W-015-08JNK-V-AC220V
2.0 0.1 0 10 10 80 NBR H 22 13 4 4 2W-020-08NK-AC220 2W-020-08JNK-AC220
2.0 0.1 0 10 10 130 EPDM H 22 13     2W-020-08NK-E-AC220 2W-020-08JNK-E-AC220
2.0 0.1 0 10 10 120 VITON H 22 13     2W-020-08NK-V-AC220 2W-020-08JNK-V-AC220
2.5 0.2 0 6 6 80 NBR H 22 13 4 4 2W-025-08NK -AC220 2W-025-08JNK -AC220
2.5 0.2 0 6 6 130 EPDM H 22 13     2W-025-08NK-E-AC220 2W-025-08JNK-E-AC220
2.5 0.2 0 6 6 120 VITON H 22 13     2W-025-08NK-V-AC220 2W-025-08JNK-V-AC220
3.0 0.25 0 5 5 80 NBR H 22 13 4 4 2W-030-08NK-AC220 2W-030-08JNK-AC220
3.0 0.25 0 5 5 130 EPDM H 22 13     2W-030-08NK-E-AC220 2W-030-08JNK-E-AC220
3.0 0.25 0 5 5 120 VITON H 22 13     2W-030-08NK-V-AC220 2W-030-08JNK-V-AC220
4.0 0.3 0 3 3 80 NBR H 22 13 4 4 2W-040-08NK-AC220 2W-040-08JNK-AC220
4.0 0.3 0 3 3 130 EPDM H 22 13     2W-040-08NK-E-AC220 2W-040-08JNK-E-AC220
4.0 0.3 0 3 3 120 VITON H 22 13     2W-040-08NK-V-AC220 2W-040-08JNK-V-AC220
3/8 4.0 0.3 0 4 4 80 NBR H 20 20 5 6 2W-040-10NK-AC220 2W-040-10JNK-AC220
4.0 0.3 0 4 4 130 EPDM H 20 20     2W-040-10NK-E-AC220 2W-040-10JNK-E-AC220
4.0 0.3 0 4 4 120 VITON H 20 20     2W-040-10NK-V-AC220 2W-040-10JNK-V-AC220
 

 

Water solenoid valve installation instructions:
1, the installation of the solenoid valve coil up and maintain the vertical position, the solenoid valve arrow or mark shall be consistent with the flow of the pipeline can not be installed in a splash of water or the leak.
2, the working medium of the solenoid valve should be clean and free of particulate impurities, dirt and member of the electromagnetic valve on the filter surface, requiring regular clean.
3, when the solenoid valve fails to timely isolation solenoid valves, and ensure the normal operation, it is best to install a bypass device.
4, in the pipeline system, installed in the branch on the way solenoid valve diameter should be less than the main pipe valve diameter.
5, before installing solenoid valves, pipes must be cleaned. It recommended before valve mounting filters, steam trap piping installation.
6, the valve can not be installed in the lower recesses of the pipe, so as to avoid steam condensate and impurities precipitated and hinder valve operation.
7, it can not be used in explosion hazardous areas.
8, in the lack of rigid pipe, it is recommended to use the valve before the pipe bracket, so as not to cause vibrations when the solenoid valve is working.
9, prior to installation, pay attention to see the product label, carefully read the instruction manual to determine whether the product meets the conditions of use.
10, before and after the valve pressure gauge to be installed on the pipe, in order to observe the pipeline pressure

 

 

 

Founded in 1965, Yuyao No.4 Instrument Factory has been a professional manufacturer of solenoid valves and has enjoyed an excellent reputation through the past more than 50 years in China.

 

The company is equipped with superior production machines, advanced process flows, complete testing systems; the products have sophisticated structure, reliable performance, fine outlook and reasonable price, covering over 40 series and 3000 specifications, having been exported to  all over the whole world since 2004.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Yuyao No. 4 Instrument Factory
Location No.66 Changxin Rd., Yuyao, Ningbo, Zhejiang, China
Contact Person Ying Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.