Pure Green 515-525nm 20mA smd led 0805 for Mobile Phone Computer LED Indicator Light , Back Lighting
Pure Green 515-525nm 20mA 400-450Mcd for 0805 SMD Chip LED Indicator Light, Back Lighting in Mobile Phone, Computer,
1. More than 10 years experience in LED industrial.
2. Biggest LED manufacturer by shipment in China,Asia.
3. Have cooperated with such big companies as Samsung,Xiaomi,etc.
4. High quality compliance with the international standard,pass CE, FCC, REACH, RoHS, UL.
5. The most important thing is that our price is more competitive with our high quality.
Package Dimension:
| Part No. | Chip Material | Lens Color | Source Color |
| DL-PCB0805SPGC-1PG120 |
InGaN |
Water Clear | Pure Green |
- Features:
- Package in 8mm tape on 7″ diameter reel.
- Compatible with automatic placement equipment.
- Compatible with infrared and vapor phase reflow solder process.
- Mono-color type.
- The product itself will remain within RoHS compliant Version.
-
- Descriptions:
- The 0805 SMD LED is much smaller than lead frame type components, thus enable smaller board size, higher packing density, reduced storage space and finally smaller equipment to be obtained.
- Besides, lightweight makes them ideal for miniature applications, etc.
-
- Applications:
- Automotive: Backlighting in dashboard and switch.
- Telecommunication: Indicator and backlighting in telephone and fax.
- Flat backlight for LCD, switch and symbol.
- General use.
- Absolute Maximum Ratings at Ta=25℃
| Parameters | Symbol | Max. | Unit |
| Power Dissipation | PD | 95 | mW |
|
Peak Forward Current (1/10 Duty Cycle, 0.1ms Pulse Width) |
IFP | 100 | mA |
| Forward Current | IF | 25 | mA |
| Reverse Voltage | VR | 5 | V |
| Electrostatic Discharge (HBM) | ESD | 400 | V |
| Operating Temperature Range | Topr | -40℃ to +85℃ | |
| Storage Temperature Range | Tstg | -40℃ to +90℃ | |
| Soldering Temperature | Tsld | 260℃ for 5 Seconds | |
Electrical Optical Characteristics at Ta=25℃
| Parameters | Symbol | Min. | Typ. | Max. | Unit | Test Condition |
| Luminous Intensity * | IV | 260 | 450 | --- | mcd | IF=20mA (Note 1) |
| Viewing Angle * | 2θ1/2 | --- | 120 | --- | Deg | IF=20mA (Note 2) |
| Peak Emission Wavelength | λp | --- | 520 | --- | nm | IF=20mA |
| Dominant Wavelength | λd | --- | 525 | --- | nm | IF=20mA (Note 3) |
| Spectral Line Half-Width | △λ | --- | 35 | --- | nm | IF=20mA |
| Forward Voltage | VF | 3.0 | 3.3 | --- | V | IF =20mA |
| Reverse Current | IR | --- | --- | 10 | µA | VR=5V |
Notes:
- Luminous Intensity Measurement allowance is ± 10%.
- θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
- The dominant wavelength (λd) is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device.
-
- Typical Electrical / Optical Characteristics Curves
-
(25℃ Ambient Temperature Unless Otherwise Noted)
- Reliability Test Items and Conditions:
-
The reliability of products shall be satisfied with items listed below:
Confidence level: 90%.
LTPD: 10%.
1) Test Items and Results:
No. Test Item Test Hours/Cycles Test Conditions Sample Size Ac/Re 1 Resistance to Soldering Heat 6 Min Tsld=260±5℃,
Min. 5sec
25pcs 0/1 2 Thermal Shock 300 Cycles H: +100℃ 5min ∫ 10 sec
L: -10℃ 5min
25pcs 0/1 3 Temperature Cycle 300 Cycles H: +100℃ 15min ∫ 5min
L: -40℃ 15min
25pcs 0/1 4 High Temperature Storage 1000Hrs. Temp: 100℃ 25pcs 0/1 5 DC Operating Life 1000Hrs. IF=20mA 25pcs 0/1 6 Low Temperature Storage 1000Hrs. Temp: -40℃ 25pcs 0/1 7 High Temperature/ High Humidity 1000Hrs. 85℃/85%RH 25pcs 0/1 2) Criteria for Judging the Damage:
Item Symbol Test Conditions Criteria for Judgment Min Max Forward Voltage VF IF=20mA --- F.V.*)×1.1 Reverse Current IR VR=5V --- F.V.*)×2.0 Luminous Intensity IV IF=20mA F.V.*)×0.7 ---
- Package Dimension:
- Reel Dimensions:
- Carrier Tape Dimensions:
Loaded quantity 3000 PCS Per reel.
Notes:
- Luminous Intensity Measurement allowance is ± 10%.
- θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
- The dominant wavelength (λd) is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device.
Notes:
- Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve.
- θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
- The dominant wavelength (λd) is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device.