Qualified Shaking System Vibration Test Machine With IEC 60068-2-64 Standard
Qualified Shaking System Vibration Test Machine With IEC 60068-2-64 Standard
Introduction:
EV series of electromagnetic vibration testing system simulates the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications. In the laboratory, with the aid of vibration testing system, simulations of reproduction of sinusoidal, random, resonant search and dwell, classical shock and road models, etc. can be achieved. It is essential for product quality assurance, new product research and development.
Features:
- Dual magnetic structure;
- Frameless armatures;
- Pneumatic load support;
- Rugged trunnion design with air isolation;
- Active armature suspension system;
- Small waveform distortion, high carrying capacity, good guidance quality;
- Protection functions for safety interlock;
- Good compatibity with slip table head expander, climatic test chamber, air isolation mounts, etc.
Calculate Formular for Exciting Force:
Specifications:
| Model | EV103 | EV203 | EV106 | EV206 | EV210 | EV220 |
| Vibration Generator | VG300/25 | VG300/40 | VG600/25 | VG300/50 | VG1000/50 | VG2000/50 |
| Frequency(Hz) | 2-4000 | 2-2500 | 2-3000 | 2-3000 | 2-3000 | 2-2500 |
| Max Exiting Force(kg.f) | 300 | 300 | 600 | 600 | 1000 | 2000 |
| Max. Displacement (mmp-p) | 25 | 38 | 25 | 50 | 50 | 50 |
| Max. Acceleration(g) | 100 | 100 | 100 | 100 | 100 | 100 |
| Max. Velocity(cm/s) | 200 | 120 | 180 | 200 | 200 | 200 |
| Payload(kg) | 110 | 120 | 200 | 200 | 300 | 400 |
| Armature Mass(kg) | 3 | 3 | 6 | 6 | 10 | 20 |
| Armature Diameter(mm) | φ150 | φ150 | φ200 | φ200 | φ240 | φ320 |
| Cooling Method | Forced Air Cooling | |||||
| Vibration Generator Weight(kg) | 460 | 460 | 720 | 920 | 1100 | 1600 |
| Vibration Generator Dimension L*W*H(MM) | 750*560*670 | 750*555*670 | 800*600*710 | 800*600*710 | 845*685*840 | 1200*870*1100 |
| Power Amplifier | Amp3k | Amp3k | Amp6k | Amp6k | Amp12k | Amp22k |
| Cooling Method | Forced Air Cooling | |||||
| Power Amplifier Weight(kg) | 250 | 250 | 320 | 320 | 350 | 500 |
| Power Amplifier Dimension L*W*H(MM) | 800*550*1250 | 800*550*1250 | 800*550*1250 | 800*550*1250 | 800*550*1520 | 800*550*1520 |
| Utility Requirements |
3-phase AC380V ±10% 50Hz | |||||
| Aggregate Capacity(KW) | 8 | 9 | 18 | 20 | 25 | 35 |
Common Standards:
- IEC 60068-2-64 Environmental Testing Part 2: Test methods –Test Fh: Vibration, broadband randomand guidance
- EIA-RS-186 Standard Test Methods for Passive Electronic. Component Parts. IEC Publication 68: Basic Environmental Test
- JIS C 0040:1999 Environmental testing Part 2: Tests -- Test Fc: Vibration (sinusoidal)
- MIL-STD 167 Department of Defense Test Method Standard – Mechanical Vibrations of Shipboard Equipment (Type I – Environmental and Type II – Internally-Excited)
- MIL-STD-202 Electronic and Electrical Component Parts
- MIL-STD-750 Test Methods for Semiconductor Devices
- MIL-STD-810 Department of Defense Test Method Standard for Environmental Engineering Considerations and Laboratory Tests
- NAVMAT P-9492 Navy Manufacturing Screening Program that provides guidance concerning the use of temperature cycling and random vibration as manufacturing screens for defects in both parts and workmanship.
- RTCA DO-160 Section 8 Vibration
Detailed Picturers: