Random Vibration Test Machine For Aerospace Meet NASA-STD-7001A
Random Vibration Test Machine For Aerospace Meet NASA-STD-7001A
Vibration Test Systems
EV series of electromagnetic vibration testing system simulate the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications. In the laboratory, with the aid of vibration testing system, simulations of reproduction of sinusoidal, random, resonant search and dwell, classical shock and road models, etc. can be achieved. It is essential for product quality assurance, new product research and deve
Technical Specifications
| Air Cooled Vibration Test System 50kgf-1100kgf | ||||||||||
| Model | EV1005 | EV101 | EV202 | EV203 | EV204 | EV206 | EV207 | EV210 | EV210B | EV310 |
| Amplifier Model | PA501EF | LPA102EF | LPA202EF | LA3K | LA4K | LA6K | LA7K | LA10K | ||
| Shaker Model | A005S12 | A01S12 | A02S12 | A03S15 | A04S15 | A06S20 | A07S23 | A11S24 | A11S34 | A11T24 |
| Rated Sine Force(KN/Kgf) | 0.55/55 | 1/100 | 2/200 | 3/300 | 4 /400 | 6 /600 | 7 /700 | 11/1100 | ||
| Rated Shock Force(KN/Kgf) | 1/100 | 2/200 | 4/400 | 6/600 | 8 /800 | 12 /1200 | 14 /1400 | 22/2200 | ||
| Frequency Range(Hz) | 5-6000(10K) | 5-6000 | 5-4500 | 5-4500 | 5-4000 | 5-4000 | 5-4000 | 5-3000 | 5-3000 | 5-3000 |
| Max. Acceleration Sine/Random(g) | 30/30 | 65/60 | 80/60 | 100/60 | 85/60 | |||||
| Max. Velocity(m/s) | 1.6 | 1.8 | 2.0 | |||||||
| Max. Displacement Peak-Peak(mm) | 20 | 25 | 40 | 51 | 51 | 76 | ||||
| Max. Payload(kg) | 20 | 100 | 100 | 120 | 120 | 300 | 300 | 300 | 300 | 300 |
| Armature Diameter(mm) | 120 | 150 | 200 | 230 | 240 | 336 | 240 | |||
| Resonance Frequency (Hz)(±5%) | 5,000 | 4,700 | 3,500 | 2,900 | 2,800 | 3,000 | 3,500 | 2,500 | 2,500 | 2,500 |
| Effective Moving Mass(kg) | 1.7 | 1.5 | 2.5 | 3 | 4 | 6 | 7 | 11 | 13 | |
| Blower | Built-in | HB751 | B751 | B112 | B402 | |||||
| Blower Power | 200W | 0.75kw | 1.1kw | 4kw | ||||||
| Blower Volume Flow Rate/Pressure | 2.3m3/min ;20kpa | 11m3/min ;2.11kpa | 23m3/min ;4.7kpa | |||||||
| System Power | 1kVA | 3kVA | 4.6kVA | 6kVA | 7kVA | 17kVA | 18kVA | 23kVA | ||
| Air Cooled Vibration Test System 2000kgf -3200kgf | |||||||||
| Model | EV220 | EV320 | EV222 | EV222B | EV322 | EV422 | EV232 | EV232B | EV432 |
| Amplifier Model | LA20K | LA20K | LA30K | ||||||
| Shaker Model | A20S32 | A20T32 | A20S34 | A20S44 | A20T34 | A20F34 | A30S34 | A30S44 | A30F44 |
| Rated Sine Force(KN/Kgf) | 20/2000 | 24/2400 | 22/2200 | 32/3200 | |||||
| Rated Shock Force(KN/Kgf) | 40/4000 | 45/4500 | 44/4400 | 64/6400 | |||||
| Frequency Range(Hz) | 5-2700 | 5-2500 | 5-3000 | 5-3000 | 5-3000 | 5-2,800 | 5-3000 | ||
| Max. Acceleration Sine/Random(g) | 90/60 | 85/60 | 100/60 | 100/60 | 90/60 | 70/60 | 100/60 | 85/60 | |
| Max. Velocity(m/s) | 2.0 | ||||||||
| Max. Displacement Peak-Peak(mm) | 51 | 76 | 51 | 51 | 76 | 100 | 51 | 100 | |
| Max. Payload(kg) | 300 | 300 | 300 | 300 | 400 | 400 | 500 | ||
| Armature Diameter(mm) | 320 | 320 | 342 | 442 | 342 | 342 | 342 | 442 | 442 |
| Resonance Frequency (Hz)(±5%) | 2,200 | 2,200 | 2,600 | 2,600 | 2,700 | 2,400 | 2,500 | ||
| Effective Moving Mass(kg) | 24 | 24 | 24 | 25 | 30 | 30 | 30 | 35 | |
| Blower | B752 | ||||||||
| Blower Power | 7.5KW | ||||||||
| Blower Volume Flow Rate/Pressure | 41m3/min ;2.6kpa | ||||||||
| System Power | 42kVA | 42kVA | 56kVA | ||||||
| Air Cooled Vibration Test System 4000kgf -7000kgf | |||||||||||
| Model | EV240 | EV240B | EV440 | EV250 | EV350 | EV450 | EV260 | EV360 | EV460 | EV370 | EV470 |
| Amplifier Model | LA40K | LA50K | LA60K | LA70K | |||||||
| Shaker Model | A30S34 | A30S44 | A30F44 | A50F44 | A50T44 | A50F44 | A50S44 | A50T44 | A50F44 | A70T45 | A70F45 |
| Rated Sine Force(KN/Kgf) | 40/4000 | 40/4000 | 40/4000 | 50/5000 | 50/5000 | 50/5000 | 60/6000 | 70/7000 | |||
| Rated Shock Force(KN/Kgf) | 80/8000 | 80/8000 | 80/8000 | 100/10000 | 100/10000 | 100/10000 | 120/12000 | 140/14000 | |||
| Frequency Range(Hz) | 5-3,000 | 5-3,000 | 5-3,000 | 5-2,800 | 5-2,700 | 5-2,500 | 5-2,800 | 5-2,700 | 5-2,500 | 5-2,500 | |
| Max. Acceleration Sine/Random(g) | 100/60 | 115/60 | 100/60 | 100/60 | 90/60 | 83/60 | 100/60 | 100/60 | 100/60 | 100/60 | |
| Max. Velocity(m/s) | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 1.8 | 1.8 | 1.9 | 1.8 |
| Max. Displacement Peak-Peak(mm) | 51 | 51 | 100 | 51 | 76 | 100 | 51 | 76/63 | 100 | 76 | 100 |
| Max. Payload(kg) | 500 | 500 | 500 | 500(Optional up to 2000 ) | 500 | 500(Optional up to 2000 ) | 500 | 1000(Optional up to 2000) | 1000 | ||
| Armature Diameter(mm) | 342 | 442 | 442 | 442 | 442 | 442 | 442 | 442 | 442 | 452 | 452 |
| Resonance Frequency (Hz)(±5%) | 2,500 | 2,500 | 2,500 | 2,400 | 2,400 | 2,100 | 2,400 | 2,400 | 2,100 | 2,100 | 2,100 |
| Effective Moving Mass(kg) | 30 | 30 | 35 | 50 | 55 | 60 | 50 | 55 | 60 | 63 | 70 |
| Blower | B153 | B223 | B303 | ||||||||
| Blower Power | 15kw | 22kw | |||||||||
| Blower Volume Flow Rate/Pressure | 82m3/min ;7.3kpa | 82m3/min ;8.5kpa | |||||||||
| System Power | 56+20kVA | 75+20kVA | 85+30kVA | 95+30kVA | |||||||
| Water Cooled Vibration Test System 6000kgf -25000kgf | |||||||
| Model | EVW360 | EVW390 | EVW3100 | EVW3120 | EVW3160 | EVW3200 | EVW3250 |
| Amplifier Model | LA60K | LA90K | LA100K | LA120K | LA160K | LA200k | LA250K |
| Shaker Model | E60T45 | E90T45 | E100T55 | E120T55 | E160T65 | E200T65 | E250T67 |
| Rated Sine Force(KN/Kgf) | 60/6000 | 90/9000 | 100/10000 | 120/120000 | 160/16000 | 200/20000 | 250/25000 |
| Rated Shock Force(KN/Kgf) | 120/12000 | 90/18000 | 200/20000 | 250/25000 | 320/32000 | 400/40000 | 500/50000 |
| Frequency Range(Hz) | 5-2,700 | 5-2,700 | 5-2,500 | 5-2,500 | 5-2,200 | 5-2,200 | 5-2,000 |
| Max. Acceleration Sine/Random(g) | 100/60 | 125/60 | 100/60 | 100/60 | 100/60 | 100/60 | 100/60 |
| Max. Velocity(m/s) | 2.0 | ||||||
| Max. Displacement Peak-Peak(mm) | 76/63 | ||||||
| Max. Payload(kg) | 1000, (optional2,000 ) | ||||||
| Armature Diameter(mm) | 450 | 450 | 550 | 550 | 650 | 650 | 670 |
| Resonance Frequency (Hz)(±5%) | 2,300 | 2,300 | 2,100 | 2,100 | 1,800 | 1,800 | 1,600 |
| Effective Moving Mass(kg) | 60 | 70 | 90 | 90 | 150 | 150 | 180 |
| Blower | C1 | C2 | |||||
| Blower Power | 100 | 100 | 100 | 100 | 220 | 220 | 220 |
| Blower Volume Flow Rate/Pressure | 150L/min 0.25-0.4Mpa | 200L/min 0.25-0.4Mpa | |||||
| System Power | 125 | 160 | 200 | 200 | 230 | 250 | 320 |
Meets Standards
IL-STD, DIN, ISO, ASTM, IEC, ISTA, GB, GJB, JIS, BS etc.
Key Applications:
- Automotive parts and systems - qualification testing
- Electronic assembly, computer equipment testing
- Avionics and military hardware testing
- Satellite component testing
- Product and package testing
- General stress screenin
Features
- Rugged suspension system and linear motion guiding, strong carrying capacity, good guiding functions, high stability;
- Load center airbag has high static stiffness and low dynamic stiffness, strong carrying capacity, perfect performance on amplitude variation;
- High efficiency D class power switching, 3-sigma peak current, provide finest power consumption and minimize harmonic distortion;
- Quick self-diagnosis with safety interlock, high safety reliability;
- Airbag shock isolation device for vibration platform without the need of additional foundation, perfect reproduction of vibrational wave and reduce vibration transmittance;
- Provide horizontal and vertical expansion platform for different application;
- Simple controller operation.
Package
Bubble Bags + Vacuum Packing + Plywooden Cases
Get in Touch