3 Meter 8 Strand Multimode MPO MTP Cable with MPO-LC Connector for QSFP/SR Module

Price Negotiable
Price: 6~15
MOQ: 1~10000
Delivery Time: within 2 weeks
Brand: New Light
Product Description
3 Meter MPO MTP Cable OM3 8 Strand Multimode Fiber Optic Cable For QSFP / SR Module
Product Description

3 Meters MPO/MTP(Female)-LC OM3 8 strands Fiber optical cable for QSFP+SR module

Standards Compliance
  • Jacketed cable is compliant with NFPA 262 Optical Fiber Nonconductive Plenum (OFNP) or IEC-60332 Low Smoke Zero Halogen (LSZH) flame rating
  • Compliant to Directive 2002/95/EC (RoHS) and REACH SvHC
  • MPO connector complies with IEC-61754-7 & EIA/TIA-604-5
Features
  • Connector End face: MPO end face geometry requirements: EN50377-15-1
  • Polishing Quality: Polished end-face quality: IEC61300-3-35
  • Designed for data center solutions supporting 10 Gigabit Ethernet, Fiber Channel or Infiniband
  • Complies with data center standards EN50173-5 and ISO/IEC 24764
Optimized Performance

Assemblies constructed with low loss MPO/MTP OECE proprietary MT polishing provides low insertion loss and high return loss, minimizing variability for improved channel link loss performance.

Technical Specifications
Parameters Standard Fiber Cable Assemblies
Fiber Type SM(G.652/G.657A) | MM(OM1/OM2/OM3)
Jacket Materials LSZH /OFNR/PVC
Connector Type SC/LC/ST/LC/MU/MTRJ/MPO/E2000
Ferrule Materials Ceramic
Testing Wavelengths 1310±30/1550±30nm | 850±30/1300±30nm
Insertion Loss(dB) TIA/EIA-455-107 ≤ 0.3dB (PC/UPC/APC) | ≤ 0.3dB (PC/UPC)
Return Loss(dB) TIA/EIA-455-107 ≥45dB(PC/UPC) ≥55dB(APC) | ≥35dB(PC/UPC)
Exchangeability ≤ 0.2dB
Cable Assemblies Pigtail/Simplex/Duplex/Fan-out Patchcord
Operating Temperature (°C) -10~ +70
Storage Temperature (°C) -40 ~ +85
Package 1unit/bag
*All values specified are with connectors.
MPO Detail

MPO patch cables are used to make the interconnections between the MPO cassettes or connections to active equipment with MPO/MTP interface.

In cases where an MPO patch cord is connected (through an MPO coupler) to another MPO patch cable, one of the two MPO connectors must be male (equipped with pins).

MPO patch cables are available in 3 different wire map configurations: Straight, Total Flipped or Pair Flipped.

MPO patch cables are available in multi-mode and single-mode fiber cable.

Applications

Performance of Assemblies MTP / MPO Termination:

Type/Performance Singlemode(APC polish) Multimode(PC / Flat Polish)
Standard | Elite Low Loss Standard | Elite Low Loss
Maximum Insertion Loss ≤ 0.75dB | ≤ 0.35dB ≤ 0.60dB | ≤ 0.35dB
Return Loss ≥ 50dB | N/A
Operating Temperature -40°C to 80°C 40°C to 80°C
Test Wavelength 1310nm 850nm
3 Meter MPO MTP OM3 8 Strand Multimode Fiber Optic Cable

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company NEW LIGHT OPTICS TECHNOLOGY LIMITED
Location Room C , floor 9 Wing Lee Building ,72-76 Wing Lok Street , Sheung Wan , HongKong
Contact Person Alice

Request A Quote

Please check your email address.
Your message must be at least 20 characters.