Expandable Commercial Ups Battery Backup , 200KVA Three Phase Online Ups Unit
CNG330 Series Low Frequency Online UPS 10-200KVA
Model:CNG330 10-200KVA(3Ph/3Ph)
Nominal Input Voltage: 380/400/415VAC
Output Power Factor:0.8
| Model power | CNG330 10-200KVA | |||||||||||
| 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | ||
| Capacity | 8KW | 12 KW | 16 KW | 24 KW | 32 KW | 48 KW | 64 KW | 80 KW | 96KW | 128 KW | 160 KW | |
| Input | ||||||||||||
| Rated voltage | 400 Vac three-phase | |||||||||||
| Voltage range | ±20% | |||||||||||
| Frequency range | 45-65Hz | |||||||||||
| Power factor | >0.92with harmonic filter | |||||||||||
| Current harmonic distortion | <5%with harmonic filter | |||||||||||
| Soft Start | 0-100% in10" | |||||||||||
| Bypass Input | ||||||||||||
| Rated voltage | 400Vac single-phase | |||||||||||
| Permitted voltage range | ±15%(selectable from ±10% to ±25% from front panel) | |||||||||||
| Rated frequency | 50/60Hz | |||||||||||
| Permitted frequency range | ±2%(selectable from ±1% to ±5% from front panel) | |||||||||||
| Standard features | Back Feed protection; split bypass line | |||||||||||
| Batteries | ||||||||||||
| Type | Maintenance-free lead-acid VRLA AGM / GEL;NICd | |||||||||||
| Battery voltage | 384VDC | 480VDC | ||||||||||
| Maximum recharge current(A) | 0.2×C10 | |||||||||||
| AC ripple voltage | <1% | |||||||||||
| Inverter Output | ||||||||||||
| Number of phases | 3+N | |||||||||||
| Rated voltage(V) | 400Vac | |||||||||||
| Regulation of the output voltage | 380~424Vac phase/neutral(from control panel) | |||||||||||
|
Crest factor |
3:1 | |||||||||||
| Static stability | ±1% | |||||||||||
| Dynamic stability | ±5% | |||||||||||
| Frequency | 50/60Hz configurable | |||||||||||
| Overload | 110% 125% 150% of the rated current for 5h/10'/1' | |||||||||||
| Frequency stability | ±0.05% on mains failure;±2%(selectable from ±1% to ±5%)with mains supply present | |||||||||||
| Remote signaling | Volt free contacts | |||||||||||
| Remote controls | EPO and Bypass | |||||||||||
| Communication | RS232 + romote contacts | |||||||||||
| Operation temperature | 0ºC/ + 40ºC | |||||||||||
| Relative humidity | <95% non condensing | |||||||||||
| Noise | 54dBA at 1m | 50-65dBA at 1m | ||||||||||
| Protection degree | IP20 | |||||||||||
| Efficiency smart mode | up to 98% | |||||||||||
| Compliance | Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC) |
|||||||||||
Application:
Servers,
Local area Network(LAN),
Data centers,
Telecommunications,
Electro-medical equipment
High intelligence and reliable power supply:
- Maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
- The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
- On-line double conversion technology (VFI) with isolation transformer on the inverter output.
- Watch & Save 3000 software as standard and can be remotely monitored using the Power Net Guard system from anywhere in the world.
- Additional battery extension packs allow the standard battery routine to be extended up to several hours.
Maximum battery care:
- Battery deep discharge protection;
- Temperature compensating charger;
- Built-in automatic and manual battery test feature.
Simple to install:
Capability to install the UPS into any distribution system(neutral not required on rectifier input);
Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (Necessary on UPS without an output transformer).
High reliability:
- Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes)
- An isolation transformer on the inverter output;
- Full microprocessor control with no-break static and manual bypasses;
- IGBT technology.
Other characteristics:
- 0.8 power factor, suitable for powering ICT and Industrial loads;
- High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD with several languages;
Back feed protection: To avoid energy feeding back into the mains supply cause a fault occur.
Maximum reliability and availability:The UPS continue to work in parallel even if one of the interconnecting communication cables is disconnected (CLOOSED LOOP).
Low consumption level:selectable Economy Mode efficiencies >98%
Expandability: parallel up to 8 units and can be expanded any time to suit power requirements without influencing the initial investment.
Sales Service:
1. 2% spares together with shipment for urgent issue.
2. All of the necessary documents such as drawing, manaul etc.
3. We will provide the online service by mail
4. Online Guide will be provied all the time. We also can desptach engineer to assist you solve the problem if necessary. But you are requested to pay for the cost of ticket, hotel etc.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.