Customized Electricity High Power UPS , Uninterruptible Power System 220V / 384V 10 - 100KVA
Customized Electricity UPS Uninterrupted Power Supply 220V / 384V 10 - 100KVA
Application:
Petroleum, chemical industry, gas and power station and so on.
Features:
- Adopt full digital control technology
- Intelligent detection and monitoring function
- Digitally control the static switch with zero switch
- Full isolation between input and output
- Super low output zero earth voltage
- DC UPS isolated with utility power completely
- Cubical design with power standard (customization)
- Multifunctional protection for overvoltage, under voltage, over current, short circuit and over temperature and so on.
- Large-screen LCD monitor with Chinese and English operation interface
- Ultralong 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen optional)
- Static bypass has a strong anti-overload capability
Control system:
It adopts microprocessor bus control technology, three core processor controlling rectification, inversion and parallel connection respectively, to ensure the real-time control of the rectifier, inverter and static switch and the coordination of every power part, characterized by increased control of aging, higher reliability, enhance of the efficiency of the whole UPS system and the output technical parameters are better than that of the device with same capacity.
Rectifier:
6 pulse or 12 pulse fully controlled bridge (6 or 12 SCR) compose rectifier. Its function is to input AC 3880V to DC220V or so by rectification. “slope” start (soft start) is the control feature, which means output voltage of the rectifier increase from 0V to 220V within 10 second and has no impact on the power grid.
Inverter:
SPWM(sinusoidal pulse width modulation) , formed by 6 IBGT high power tubes, is composed of full-bridge-control.
Large Capacity of Overload of the UPS Inverter:
| Load | |
| 110% | 60' |
| 125% | 10' |
| 150% | 1' |
| 200% single phase | 30" |
Good Capacity of Resistance to Output Short Circuit Current Limiting and Period Load Impact
Static switch
Not sync automatically switch:When the bypass of the UPS lose sync with the inverter, system can automatically implement not sync switch; When the bypass exceed the limitation, UPS will detect the bypass every 20ms, when the phase angle difference of bypass and the inverter turn to normal range, not synchronized bypass shifting can be realized.
Intelligent monitoring:
RS232/RS485, passive contact and power transmitter, which finally realize Intelligent monitoring.
Unique option:
- SNMP card
- Dry contact card
- Signal transmitter
- Bypass isolation and voltage regulation
- Increase feeder circuit (standard for 8 loops)
- 12 pulse rectifier
- The appearance of special models(standard dimension:800×600×2260mm)
Technical Specification:
| CND310 10KVA-100KVA | ||||||||||||||
| Model (KVA) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | |||||
| Rating capacity(KW) | 8 | 12 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | |||||
| Rating voltage | 220V(one-phase) /380V(three phase) | |||||||||||||
| AC input | ||||||||||||||
| Voltage range | ±25% | |||||||||||||
| Frequency range | 50,60Hz±10% | |||||||||||||
| Soft start | 0-100% in 5” | |||||||||||||
| Power factor | 0.95(with input filter) | |||||||||||||
| Bypass input | ||||||||||||||
| Permitted voltage range | ±15% | |||||||||||||
| Frequency range | 50/60Hz±5% | |||||||||||||
| Output | ||||||||||||||
| Voltage accuracy | 220V±1%(steady load) 220V±3%( fluctuating load) | |||||||||||||
| Permitted Frequency range | 50/60Hz±0.05Hz(powered by battery) | |||||||||||||
| Power factor | 0.8 | |||||||||||||
| THD | Linearload<2%, non linear load<4% | |||||||||||||
| Dynamic transients | <5% | |||||||||||||
| Current crest ratio | 3:1 | |||||||||||||
| Overload capacity | Normal in 110% load, 125% for 10min | |||||||||||||
| Efficiency | Double switch:94%, ECO:98% | |||||||||||||
| DC | ||||||||||||||
| Battery voltage | 220V | |||||||||||||
| Cutoff voltage | 185V | |||||||||||||
| Maximum discharge current | 36A | 55A | 73A | 109A | 145A | 181A | 218A | 291A | 364A | |||||
| Penal display | ||||||||||||||
| LCD | Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge current, accident display, warning | |||||||||||||
| Environment | ||||||||||||||
| Temperature | 0ºC-40 ºC | |||||||||||||
| Humidity | 0-95%(no condensing) | |||||||||||||
| Storage temperature | -25 ºC—55 ºC | |||||||||||||
| Altitude | <1500m | |||||||||||||