Ultrashape Power Lipo Slim Machine Slimming Treatment Machine
Ultrashape combines the Fat 3D positioning system & FUS technology & Waves vest technology to destroy the walls of fat cells, releasing the fat in the form of triglycerides. Then the triglycerides are processed through the liver and eliminated from the body naturally with surrounding tissue, nerves, and muscle unharmed.
Fat 3D positioning system & FUS technology & Waves vest
Fat 3D positioning system: Capable of accurate positioning of fat cells, and calculate the energy required for every shot, to avoid repeating the same applied to the treatment area to play. In ensuring the effectiveness of the premise, to prevent postoperative uneven, redness, burns
and other adverse symptoms.
FUS technology: Under the sonic fat cell membrane was adjusted with a similar resonance frequency, so that it does not damage blood vessels, nerves and connective tissue under the premise of effectively shatter the fat cell membrane. Focused ultrasound energy directly to subcutaneous fat can make the body surface temperature rise of less than 0.5 centigrade,
effective way to avoid burns and other adverse reactions.
Waves vest: Rapid downsizing often bring loose skin, orange peel and other phenomena, but Ultrasharp gifted plastic vest wave function, can effectively tighten the skin, remove cellulite. So
you have a perfect curve.
Parameters
Input Voltage: 220V/110V
Rated Current: 4A
Line Frequency: 50/60HZ
Main Components:
●Console
●Camera
●VDF Power transducer
●U-Sculpt Power transducer
Dimensions [W x D x H]
Outline Max Dimension: 49x56.5x198cm
Console:38.2x47.8x105cm
Height of system with adjustable mast: 90–131.7cm
Transducer [Dia. x Height x Length]
VDF Power Transducer:126x155x193mm
U-Sculpt Power Transducer:110x123x154mm
Weights
Net Weight :45kg.
Coolant used in the cooling system:
●Purified distilled water
Operating Principles
The Ultra Shape Power system offers a unique solution for non-invasive ultrasonic body contouring, based on a state-of-the-art application of focused ultrasound, monitored by real-time video camera imagery. The procedure is performed on an outpatient basis with no requirements of operating facilities or down-time.
The Ultra Shape Power system's approach to body contouring is based on its technology of:
- Focused ultrasound, delivered by a proprietary ultrasound transducer.
- Parameters that allow ultrasound energy to penetrate the skin and be concentrated within the subcutaneous fat, using a proprietary technology which enables controlling the acoustic field distribution.
- Targeting of a defined volume of fat with each pulse of energy.
- Delivery of energy without harming the skin, blood vessels, nerves or connective tissue.
- Real-time video tracking and guidance system, which allows homogeneous coverage of the treatment area.
SAFETY AND REGULATORY INFORMATION
Intended Use
The Ultra Shape Power system uses focused ultrasound to produce localized mechanical motion within fat tissues and cells, for the purpose of producing mechanical cellular membrane disruption. It is intended for non-invasive aesthetic body contouring.
Intended Users
The intended users for patient treatment are physicians and other qualified health care professionals operating under the supervision of a physician.
Treating Attendant
Personnel should not operate the system until they have been fully trained in its Use.
Assessed Body Areas
The safety and efficacy of the Ultra Shape Power system have been assessed and demonstrated for body contouring of the abdomen.
Prerequisites for Treatment
The Ultra Shape Power is intended for use on patients of sound health, aged 18 years or older, with subcutaneous fat thickness of at least 1.5 cm (assessed by pinch test or commercial skin fold caliper) in the intended treatment area (abdomen, outer thighs, or flanks) prior to strapping. After strapping, the distance between the skin surface and the focal point of treatment should be verified to be at least 2.5 cm.
Caution
After marking the treatment area and positioning the patient on the treatment bed, the operator should confirm that the fat thickness in the marked treatment area is at least 1.5 cm before strapping and at least 2.5 cm after strapping.
Inclusion Criteria
- Female and male subjects, > 18 and < 65 years of age at the time of enrolment.
- Abdominal fat thickness of at least 1.5 cm prior to the initial treatment (measurement by caliper) prior to strapping,andatleast2.5cmafterstrapping.
- General good health, confirmed by medical history and skin examination of the treated area.
- BMI ≤ 30
- For women of child-bearing potential,negative pregnancy test 24 hours priorto the first treatment (measured in urine)
| Power | 800W |
| Voltage | 100-130V; 200-250V 50/60HZ |
| Treatment handpiece | VDF+U-Sculpt |
| Lifetime of handpiece | Wach 36,000 shoots |
| Package | 60*90*139cm,
Gross Weight : 70kg Volum Weight : 140kg |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.




