2M Bandwidth Clamp On Current Transformer 1000/5A Permalloy Materials

Price Negotiable
Price: Negotiable
MOQ: 3pcs
Delivery Time: 3 Days
Brand: GFUVE
Product Description

High Precision 2M Bandwidth Clamp On Current Transformer 1000/5A
 
 
In electrical and electronic engineering, a Oscilloscope AC Clamp On Current Transformer is an electrical device having jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it.
Oscilloscope AC Clamp On Current Transformer Q50A features 50 mm jaw size and high linearity. It is a ac current clamp which can measure 0-1000A cable. Product comes with a year warranty.
 
Clamp-On Current Transformers GFUVE® maintains a large in-stock inventory of Clamp-On Current Transformers including AC, Micro Clamp and Clamp-On CT Accessories for most common applications. Below is a list of all clamp-on current transformers available through GFUVE material, however, not all models are in-stock.
 
Clamp-on Current Transformer Current Clamp is a high-precision AC current converter, and can meet a variety of measuring instruments, It can be used along with many kinds of instruments and devices, such as energy meter spot calibrator, multifunctional meter, oscilloscope, digital multimeter, dual clamp Ground resistance tester, dual clamp phase volt ammeter.
 
The P50 AC clamp on Current transformer is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. The sensing head uses sliding push-fit clamp structure, safety isolation to avoid the user to contact with charged objects directly. It complies with CE standards and meets 600V CAT III safety class.
 
Applications
 
Electric energy meter calibrator (on site)
Double clamp type ground resistance tester
Double clamp type phase volt-ampere meter
Digital multi-meter
Multi-function energy meter
Power quality analyzer
Matched instruments
Calibration instrument on site
 
 
Features
 
Suitable for 1000A cable online measurement.Holding wire diameter: φ50mm
Dimension: 101mm×219mm×26mm
Load capacity: mA output≤4Ω, 1A output 0.1Ω, 5A output 2.5VA
Installation: clamp type
Output mode: lead output
 
 
Parameter
 

Electrical parameters
Ratio1000: 1 or 2000:1 (customized)
Accuracy class0.1%, 0.2%, 0.5%
Primary current0 - 1000A AC
Secondary current0 - 5A AC (customized)
Max. Cont. Input current1200A
Over voltage categoryCAT III 600V
Output signal500mA,1A,5A AC at nominal input current
Frequency range40Hz-2000Hz
Dielectric strength3KV 50Hz/60Hz at 1 minute
Temperature range-20°C to +55°C
Output2.5 meter cable with D01 connector
Max. voltage not insulated conductors600 V
StandardEN 61010-1, EN 61010-2-032, IEC60044-1
InstallationClamp type
Output modeLead output (2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm)102.9 x 219.6 x 28
Weight (g)550
Holding wire diameter (mm)φ50
Max. jaw opening (mm)50
Jaw colorBlue
Material

PC+ABS+Polycarbonate, UL94 V0

 
1000A/1A 0.1% precision Oscilloscope AC Clamp On Current Transformer With BNC connector & 4mm banana connector
 
Selection Model
 

ModelRate CurrentMax CurrentSecondary CurrentCoil RatioBurden ResistanceAccuracy
P50-200200A240A5A40:12.5VA0.5%
P50-300300A360A5A60:12.5VA0.5%
P50-400400A480A5A80:12.5VA0.5%
P50-500500A600A5A100:12.5VA0.5%
P50-600600A720A5A120:12.5VA0.5%
P50-800800A960A5A160:12.5VA0.5%
P50-10001000A1200A5A200:12.5VA0.5%
P501-100100A120A1A100:1customized0.5%
P501-200200A240A1A200:1customized0.5%
P501-300300A360A1A300:1customized0.2%
P501-400400A480A1A400:1customized0.2%
P501-500500A600A1A500:1customized0.2%
P501-600600A720A1A600:1customized0.2%
P501-800800A960A1A800:1customized0.2%
P501-10001000A1200A1A1000:1customized0.1%
P502-500500A600A500mA1000:1customized0.1%
P502-10001000A1200A500mA2000:1customized0.1%
P503-800800A960A400mA2000:1customized0.1%
P503-10001000A1200A400mA2500:1customized0.1%
P504-500500A600A250mA2000:1customized0.1%
P504-10001000A1200A250mA4000:1customized0.1%

 
Photos

 
FAQ, following questions will help you to select the matched Clamp On Current Transformer for your applications.
 
1. Please determine if you are measuring AC or DC?
GFUVE Q50A-2 is for AC measurement.
 
2. What is the maximum current you will measure?
Q50A-2 maximum current is 1200A
 
3. What size conductor will you clamp onto? This parameter determines the probe jaw size needed.
Q50A-2 can clamp conductor within diameter of 50mm
 
4. What type of probe output do you need or can you work with (mA, mV, A, AC, etc.)?
Q50A-2 can customize output with A, V.
 
5. What is the working voltage of the conductor to be measured?
GFUVE probes should be used below 600 volts
 
6. What type of termination do you need: jacks, leads or BNC?
Q50A-2 standard has 2.5meter leads. We can offer jacks or BNC… as options.
 
7. If you cannot find information you need or would like assistance, contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Location Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Contact Person Andy

Request A Quote

Please check your email address.
Your message must be at least 20 characters.