Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display
Price:
Negotiable
MOQ:
1set
Delivery Time:
1-2weeks
Brand:
GFUVE
Product Description
GF106T Current Transformer Calibration Device With Turn Ratio Transformer Test CT PT Analyzer
GF106T Portable Instrument Current Transformer calibration device is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
MAIN FUNCTIONS
| I. Current Transformer (CT) | II. Voltage Transformer (PT) |
|---|---|
| 1. Magnetization curve | 1. Excitation characteristic test |
| 2. Transformation ratio test | 2. Transformation ratio test |
| 3. Polarity | 3. Polarity |
| 4. 5% and 10% error curve | 4. Withstand test of power frequency alternating current |
| 5. Current Injecting | 5. Degauss |
| 6. Degauss | 6. Calculation of knee point value |
| 7. Withstand test of power frequency alternating current | 7. Actual secondary load test |
| 8. Automatic calculation of excitation knee point value |
8. Resistance test |
| 9. Actual secondary load test | |
| 10. Resistance test | |
PARAMETERS
| Electrical parameters | ||
|---|---|---|
| Accuracy | 0.2%, 0.5% | |
| Power supply | AC 220V±10% or AC 110V±10%, 50/60Hz | |
| Excitation voltage output | 0-2500Vrms, | |
| Excitation current output | 0-5Arms (20A peak-value) | |
| Large current output | 0-1000A | |
| Electrical parameters - continued | ||
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary winding DC resistance measurement | Range | 0.1-300Ω |
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary actual load measurement | Range | 5VA-1000VA |
| Accuracy | ≤0.5% (0.2%RD+0.3%RG)±0.1VA | |
| CT/PT phase error measurement | Accuracy | ±4min |
| Resolution | 0.01min | |
| CT ratio error measurement | Range | ≤25000A/5A(5000A/1A) |
| Accuracy | ≤0.5% | |
| PT ratio error measurement | Range | 1-500KV |
| Accuracy | ≤0.5% | |
| Standards | ||
| Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012 |
|
| Safety standards | GB 4793.1-2007 | |
| EMC | EMC standard 89/336/EEC | |
| FCC Subpart B of Part 15 Class A | ||
| IEC 1000-4-2 /3 /4 /6 | ||
| Mechanical parameters | ||
| Overall dimension (L x W x H) (mm) | 400 x 250 x 250 | |
| Weight (kg) | ≤22 | |
| Environmental conditions | ||
| Relative humidity | 90RH% | |
| Operating temperature | -10°C to +40°C | |
| Altitude | ≤1000m | |
Photo
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Location
Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Contact Person
Andy