Self - Diagnose Motor Testing Machine , Surge Testing Machine 100MHz Sampling Frequency
Motor Testing Machine For Room Air Conditioner, Room Air Conditioner Motor Testing
1. Test object: air conditioner motor
2. Technical parameters
| AC Hipot | |
| test time range/resolution | 0.5~999.9s 0.1s/step |
| Output voltage setting range and precision | AC 200~3000V ±(2%×setting value+10V) |
| breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05 mA) |
| Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
| Direction of rotation | |
| rotation | CW, CCW, still |
| Insulation resistance | |
| output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
| insulation resistance testing range/precision |
1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) |
| insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ |
| test time range/resolution | 0.5~999s 0.1s/step |
| DC winding resistance test | |
| testing range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
| test time range/resolution |
0.5~999s 0.1s/step
|
| temperature compensation function | Yes |
| temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
| precision | ±0.5°C(range: -10℃~+50℃) |
| Surge | |
| output voltage setting range/precision | 500~3000V ±(3%×display value+8V) |
| sampling frequency | 100MHz |
| waveform comparison |
area, area difference, corona and phase 3 waveforms displayed in the testing interface |
| No-load | |
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
| Low voltage start | |
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
| Stall | |
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
3. After-sales service
Self-diagnose: the testing system has the function of self-diagnose, which could diagnose itself automatically and position the failure module when switch-on the testing system.Remote control: the service engineers will check the equipment status or failure via remote control in case of problem occurs.
Modular design makes the equipment can be maintained easily.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.