Air Conditioner Motor Testing Machine, Motor Of Air Conditioner Indoor Unit

 

1. Product specification and test:

    1.1 Station: two stations

    1.2 Clamping mode: standard equipped with 8-bit clamps

    1.3 Test: Low-voltage, no-load, stall, rotation, Hipot, surge, insulation resistance and winding resistance

 

2. Technical parameters:

2.1 Low voltage start:

voltage testing range and precision AC:30~500V ±(0.5%×display value+1 words)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)

2.2 No-load:

voltage testing range and precision AC:30~500V ±(0.5%×display value+1 word)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)

2.3 Stall

voltage testing range and precision AC:30~500V ±(0.5%×display value+1 word)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)

2.4 Direction of rotation

rotation mode: Hall/MAC/inductance
rotation CW, CCW, still

2.5 AC Hipot:

Output voltage setting range and precision AC 500~3000V ±(2%×setting value+10V)
breakdown current testing range/precision 0.10~20.00mA ±(2%×setting value+0.05 mA)
Hipot current presetting alarm range Max:0.10~20.00mA;Min:0.00~20.00mA
Hipot current/resolution ±(2% display value+0.05 mA);0.01 mA
test time range/resolution 0.5~999.9s 0.1s/step
Arc detection 0~9 level

2.6 Surge:

output voltage setting range/precision 500~3000V ±(3%×setting value+8V)
sampling frequency 100MHz
waveform comparison area, area difference, corona and phase 3 waveforms displayed in the testing interface

2.7 Insulation Resistance:

output voltage setting range/precision DC 500V/1000V ±(2%×setting value+10V)
insulation resistance testing range/precision

1~500MΩ

≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)

insulation resistance alarm setting range Max: 0~500MΩ; Min: 1~100MΩ
test time range/resolution 0.5~999s 0.1s/step

      2.8 DC Winding resistance :

testing range and precision 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set.
test time range/resolution

0.5~20s 0.1s/step

 

temperature compensation function Yes
temperature probe/range DS18b20 -10.0℃~+50.0℃
precision ±0.5°C(range: -10℃~+50℃)

 

3. Service

  • The service engineers will check the equipment status or failure via remote control in case of problem occurs.
  • Self-diagnose: the testing system has the function of self-diagnose, which could diagnose itself automatically and position the failure module when switch-on the testing system.
  • Modular design makes the equipment can be maintained easily.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Qingdao AIP Intelligent Instrument Co., Ltd
Location Building B-3, Liando U Valley, No. 780 Baoyuan Road, Chengyang High-tech District, Qingdao, China

Request A Quote

Please check your email address.
Your message must be at least 20 characters.