Innovation Electronic Co.,Ltd
                                                                                                           
Verified Supplier
14 Years
Since 2012
Menu

Load Cell IPW2C 7.2kg to 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v

Price Negotiable
Price: Negotiable
MOQ: 1pc
Delivery Time: 15-30 days
Brand: inntronic
Product Description
IPW2C 7.2kg to 72kg Single Point Load Cell for static weighing
 
Special features
 

−  Accuracy class C3/C3MR and C6/C6MR with OIML-R60 test report
−  Max. capacities: 7.2 kg ... 72 kg
−  Off center load compensated(OIML R76)
−  Degree of protection IP67(according to EN 60 529)
−  Shielded connection cable
−  optimized for dynamic weighing applications

    Optional:

-   Different accuracy classes with OIML-R60 test report
−  Connection cable in six wire circuit
−  Different cable lengths
−  Aligned output, suitable for
−  Aligned output, suitable for connectionin parallel

 

 

 

TypeIPW2C
Accuracy class1)C3; C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg7.212183672 

Minimum LC verification interval (vmin)
Accuracy class C3

g1251020

Temperature effect on
zero balance (TK0)
Accuracy class C3
 

% v.
Cn /
10 K
 

±0.0194±0.0233±0.0389±0.0389±0.0389

Minimum LC verification interval (vmin)
Accuracy class C3MR

g0.512510

Temperature effect on
zero balance (TK0)
Accuracy class C3MR

% v.
Cn /
10 K
 

±0.0097±0.0116±0.0155±0.00194±0.0194
Max. platform sizemm380 x 380
Sensitivity (Cn)mV/V2.2±0.2
Zero balance0±0.12

Temperature effect on
sensitivity (TKC)3)
Temperature range
+20 ... +40℃ [+68 ... +104℉]
−10 ... +20℃ [+14 ... +68℉]

% v.
Cn /
10 K
 

±0.0175
±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Input resistance (RLC)Ω300 ... 500
Output resistance (R0)300 ... 500
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1 ... 12
Insulation resistance (Ris) at 100 VDC> 2
Nominal temp. range (BT)

°C
[°F]

−10 ... +40 [+14 ... +104]
Service temp. range (Btu)−10 ... +50 [+14 ... +122]
Storage temp. range (Btl)−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.
100mm eccentricity

% of
Emax

150
160

Lateral load limit (Elq), static

% of
Emax

300
Breaking load (Ed)300
Weight (G), approx.kg0.25

Protection class according to
EN 60 529 (IEC 529)

 IP67

Material: Measuring element
Coating
Cable sheath

 

Aluminum
Silicone rubber
PVC

 