Aolittel Technology Co.,Ltd
                                                                                                           
Verified Supplier
9 Years
Since 2017
Menu

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Price Negotiable
Price: Negotiable
MOQ: 1000 Pieces
Delivery Time: 7-10 Days
Brand: AOLITTEL
Product Description

 

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

 

 

Shortcut info

 

Product name: glass fuse; rated Voltage: AC 250V; rated current: 5A
Function: slow blow; body Size: 11 x 4mm/ 0. 4' x 0. 15' (LED)
Wire Leads length(each): 27mm/ 1 inch
Color: Clear, Silver Tone; material: glass, alloy

 

___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Specification

 

A=250V B=125V

Part

No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TBP0250A 250mA 250V 240 0.06
TBP0315A 315mA 250V 220 0.09
TBP0400A 400mA 250V 200 0.2
TBP0500A 500mA 250V 190 0.4
TBP0630A 630mA 250V 180 1.0
TBP0800A 800mA 250V 160 1.9
TBP1100A 1A 250V 140 4.2
TBP1125A 1.25A 250V 130 8.7
TBP1160A 1.6A 250V 120 10.1
TBP1200A 2A 250V 100 20.3
TBP1250A 2.5A 250V 100 40
TBP1315A 3.15A 250V 100 68
TBP1400A 4A 250V 100 100
TBP1500A 5A 250V 100 133
TBP1630A 6.3A 250V 100 172

 

 

Certifications

 

Voltage Rating

Agency

Ampere Range

Agency File Number

250V UR 250mA ~ 5A E340427(JDYX)
C-UR 250mA ~ 5A E340427( JDYX7)
CQC 250mA ~ 5A CQC16012161227
VDE 500mA,1A,1.25A,1.6A,2A,2.5A,3.15A,5A 40032053
PSE 250mA ~ 5 A Pending
KTL 250mA ~ 5 A Pending

Standards:In accordance with IEC60127-1, IEC60127-3, GB9364.1, GB9364.3.

 

 

Dimension (mm)

 

                                                           

 

 

Operating Characteristics

 

% of Ampere Rating(In)

Blowing Time

210%*In 2 min Max
275%*In 400 ms~10 s
400%* In 150 ms~3s

 

 

Average Time Current Curves

 

 

 

Installation Recommendations

 

Propose installation way as following picture.

 

A.Horizontal installation
B.Vertical installation
C.Vertical installation

 

 

Checking and replacing fuses

 

Procedure

 

Many electrical devices used in eye care have an externally accessible fuse near the electrical cord (Figure 1) that you can check and replace by following these steps.

 

Figure 1

 

  1. Disconnect the device from the electrical system.
  2. Remove the fuse from its holder. In some cases you may need a small screwdriver to unscrew the fuse holder cap.
  3. Look at the fuse wire. If there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced. If you cannot see whether the fuse is blown, follow steps 4 and 5. If the fuse is definitely blown, go to step 6.
     
  4. Set a multimeter (Figure 2) to the resistance or Ω (Ohms) setting.

Figure 2

 

5.Place one of the multimeter leads on one end of the fuse. Place the other lead on the other end of the fuse. If the reading is between 0 and 5 Ω (Ohms), the fuse is good. A higher reading indicates a bad or degraded fuse. A reading of OL (Over Limit) definitely means a blown fuse.

6.If the fuse is blown, replace the fuse with one that is exactly the same (see panel). Make sure to note the fuse amperage and voltage ratings, which should be marked on the fuse itself (Figure 3) or on the panel label near the fuse holder. Additionally, note the size and whether it is a slow-blow or a fast-blow type fuse. If there are no markings on the fuse itself or on the equipment you must consult the device's operating manual.

Figure 3

 

 

General suggestions

 

*Always disconnect equipment from electrical power before removing a fuse; not doing so may result in serious injury.
*Always replace a fuse with an identical type, and never substitute a fuse with foil or another object. This could lead to electrocution and fires.
*Keep enough stock of the fuses used in your clinic or hospital. Store each type in separate containers with a label describing the fuse's voltage and amperage, whether it is a fast-blow or slow-blow type, the size, minimum number needed (the minimum stock level), and the models of equipment that use each type of fuse.
*Check your stock of fuses frequently and order more fuses when it reaches the minimum stock level.
If possible, tape a spare fuse to the equipment so that it is available when needed.

Similar Products

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Aolittel Technology Co.,Ltd
Location NO.27,Jinlanling Street,Taigongling Village Dongguan 523829,Guangdong,China
Contact Person Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.