Overview
- PROFIBUS DP master with electrical interface for connecting the SIMATIC S7-400 to PROFIBUS at up to 12 Mbit/s (including 45.45 Kbit/s)
- For setting up additional PROFIBUS DP lines
- Communication services:
- PROFIBUS DP
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
- Time synchronization
- Easy programming and configuration over PROFIBUS
- Cross-network programming device communication through S7 routing
- Can be easily integrated into the SIMATIC S7-400 system
- Module replacement without PG
- SIMATIC H system operation for redundant S7 communication or DP master communication
- Data record routing (PROFIBUS DP)
- Adding or modifying distributed I/O during operation
Application
The CP 443-5 Extended is the communications processor of the SIMATIC S7-400 for the PROFIBUS bus system.
It relieves the CPU of communication tasks and supports additional connections.
Communication possibilities of the S7-400 using communication modules:
- As master for PROFIBUS DP according to IEC 61158/EN 50170
- Communication with programming devices and HMI devices
- Communication with other SIMATIC S7 systems
- Communication with SIMATIC S5 programmable controllers
The number of CPs that can be used is dependent on the performance range of the CPU and on the communications services used.
Function
The CP 443-5 Extended provides access to different communication services of the PROFIBUS bus system:
- PROFIBUS DP (according to IEC 61158/61784)
- PG/OP communication
- S7 communication (S7 controllers)
- Open communication (SEND/RECEIVE)
- Time synchronization
Technical data
| Product type designation | CP 443-5 Extended | |
| Communications processor CP 443-5 Extended for connection of SIMATIC S7-400 to PROFIBUS DP, S5-compatible, PG/OP and S7 communication | ||
| Transmission rate | ||
| Transfer rate | ||
| ● at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s | |
| Interfaces | ||
| Number of interfaces / acc. to Industrial Ethernet | 0 | |
| Number of electrical connections | ||
| ● at the 1st interface / acc. to PROFIBUS | 1 | |
| Type of electrical connection | ||
| ● at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS485) | |
| Supply voltage, current consumption, power loss | ||
| Type of voltage / of the supply voltage | DC | |
| Supply voltage / 1 / from backplane bus | 5 V | |
| Supply voltage | 5 V | |
| Relative symmetrical tolerance / at DC | ||
| ● at 5 V | 5 % | |
| Consumed current | ||
| ● from backplane bus / at DC / at 5 V / typical | 1 A | |
| Power loss [W] | 5 W | |
| Permitted ambient conditions | ||
| Ambient temperature | ||
| ● during operation | 0 ... 60 °C | |
| ● during storage | -40 ... +70 °C | |
| ● during transport | -40 ... +70 °C | |
| Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % | |
| Protection class IP | IP20 | |
| Design, dimensions and weight | ||
| Module format | Compact module S7-400 single width | |
| Width | 25 mm | |
| Height | 290 mm | |
| Depth | 210 mm | |
| Net weight | 0.65 kg | |
| Product properties, functions, components / general | ||
| Number of units | ||
| ● per CPU / maximum | 14 | |
| ● Note | The number of CPs that can be operated as DP masters depends on the number of CP 443-1 Advanced processors operating in the S7-400 station as PROFINET IO controllers. Up to 10 CPs can be operated in total: up to 4 as PROFINET IO controllers (CP 443-1 Advanced); up to 10 as DP masters (CP 443-5 Extended) | |
| Performance data / open communication | ||
| Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 32 | |
| Amount of data | ||
| ● as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 240 byte | |
| Performance data / PROFIBUS DP | ||
| Service / as DP master | ||
| ● DPV1 | Yes | |
| Number of DP slaves / on DP master / usable | 125 | |
| Amount of data | ||
| ● of the address area of the inputs / as DP master / total | 4096 byte | |
| ● of the address area of the outputs / as DP master / total | 4096 byte | |
| ● of the address area of the inputs / per DP slave | 244 byte | |
| ● of the address area of the outputs / per DP slave | 244 byte | |
| Performance data / S7 communication | ||
| Number of possible connections / for S7 communication | ||
| ● maximum | 48 | |
| Performance data / multi-protocol mode | ||
| Number of active connections / with multi-protocol mode | ||
| ● without DP / maximum | 59 | |
| ● with DP / maximum | 54 | |
| Configuration software | ||
| ● required | STEP 7 V5.4 SP4 or higher and NCM S7 for PROFIBUS | |