NSX100F 36 KA LV429630 Molded Case Circuit Breaker
Schneider NSX100F 36 kA LV429630 Circuit breaker 415 VAC 3p3d 100A Circuit breaker
Features
NSX Molded Case Circuit Breakers is a full range of high performance molded case circuit breakers (MCCB) in 2 frame sizes designed to meet your needs from thermal-magnetic to advanced Micrologic trip units. This range will soon feature integrated earth leakage protection.
Specifications:
- Flexible installation: any position; switchboard or wall-mounted
- Nominal current: 16 to 630 A
- 9 Breaking capacities for the 2 sizes of circuit breakers:
- up to 250 A: 25, 36, 50, 70, 100, 150, 200 kA at 415 V
- up to 630 A: 36, 50, 70, 100, 150, 200 kA at 415 V
- both size of circuit breakers with 75 & 100 kA at 690 V - 1, 2, 3 and 4 pole versions available
- Large range of electronic and thermal-magnetic protections
- Advanced trip unit with integrated power metering: I, U, P, E, THD, f, CosPhi
- Interchangeable trip-units to upgrade your panel with smarter functions
- Plug and ready wiring system and communicating accessories
- Wealth of options for auxiliaries and accessories (field installable)
- Integrated earth leakage protection via Micrologic Vigi coming soon in Q4 2018 (earth leakage circuit breaker - ELCB)
-
BENEFITS
Easy and efficient
- Two standardized frame sizes for your convenience
- Save space, time and effort with integrated earth leakage protection (ELCB), in the molded case circuit breaker (MCCB) frame size
- Easy to swap trip units and standardized accessories over time
- Wide range of online and offline software tools that help to improve productivity at all stages of your project
Technical Dastsheet:
| poles description |
3P
|
|
|---|---|---|
| protected poles description |
3t
|
|
| [In] rated current |
100 A at 40 °C
|
|
| [Ue] rated operational voltage |
690 V AC 50/60 Hz
|
|
| network type |
AC
|
|
| network frequency |
50/60 Hz
|
|
| suitability for isolation |
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2 |
|
| utilisation category |
Category A
|
|
[Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508 |
|
|---|
| Performance level |
F 36 kA 415 V AC
|
|
|---|---|---|
| trip unit name |
TM-D
|
|
| trip unit technology |
Thermal-magnetic
|
|
| trip unit protection functions |
LI
|
|
| control type |
Toggle
|
|
| Circuit breaker mounting mode |
Fixed
|
| mounting support |
Backplate
|
|
|---|---|---|
| upside connection |
Front
|
|
| downside connection |
Front
|
|
| connection pitch |
35 mm
|
|
| protection type |
L : for overload protection (thermal)
I : for short-circuit protection (magnetic) |
|
| trip unit rating |
100 A at 40 °C
|
|
| Long-time pick-up adjustment type Ir (thermal protection) |
Adjustable
|