3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch
3RT1054-6AP36 115 A 55 kW MOTOR CONTACTOR 400VAC/ DC 220-240V 2NO 2NC CONTACTOR
Power contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional screw terminal
3RT contactors, sizes S00 to S12
Our power range:
- Contactors for switching motors:
- Size S00: 3RT201 up to 7.5 kW
- Size S0: 3RT202 up to 18.5 kW
- Size S2: 3RT203 up to 37 kW
- Size S3: 3RT204 up to 55 kW
- Sizes S6 to S12: 3RT10 up to 250 kW
- Vacuum contactors for switching motors, see SIRIUS 3RT12 and 3TF6 Vacuum Contactors:
- Sizes S10 and S12: 3RT12 up to 250 kW
- Size 14: 3TF6 up to 450 kW
Ratings of three-phase motors
The quoted rating (in kW) refers to the output power on the motor shaft (according to the nameplate).
The power rating specifications of the contactors in kW (in accordance with IEC 60947-4-1, Table G) are guide values for 4-pole standard motors at 50 Hz AC and specified voltage (e.g. 400 V AC). The actual starting and rated data of the motor to be switched must be considered when selecting the units. The motor current, motor protection device and the permissible contactor current according to the utilization category must be aligned with each other.
Operating mechanism types
3RT1 contactors
The following control and/or operating mechanism versions are available in sizes S6 to S12:
- Standard operating mechanism with economy circuit for AC and DC operation (switchover from closing coil to holding coil)
- Solid-state operating mechanism
Overvoltage damping of the operating mechanism coil is already integrated in the electronics for contactors with solid state operating mechanisms. The operating mechanisms are powered via a supply voltage with an operating range from 0.8 to 1.1 x Us, optionally also controlled depending on the chosen mode of operation. Alternatively, control is also possible via the separate 24 V DC control signal input. Various rated voltage ranges for AC/DC control are available.
The following versions are available:- With two operating modes: Direct control or via CPU input
- As above, but with additional remaining lifetime indicator (RLT)
- With fail-safe PLC input for simplification of safety applications (without mode of operation selection)
Technical data
| SIRIUS |
| Power contactor |
| 3RT1 |
| S6 |
| No |
| Yes |
| 21 W |
| 7 W |
| 5.2 W |
| 8 kV |
| 6 kV |
| 690 V |
| IP00; IP20 on the front with cover / box terminal |
| IP00 |
| 8,5g / 5 ms, 4,2g / 10 ms |
| 8,5g / 5 ms, 4,2g / 10 ms |
| 13,4g / 5 ms, 6,5g / 10 ms |
| 13,4g / 5 ms, 6,5g / 10 ms |
| 10 000 000 |
| 5 000 000 |
| 10 000 000 |
| Q |
| 2 000 m |
| -25 ... +60 °C |
| -55 ... +80 °C |
| 3 |
| 3 |
| 1 000 V |
| 160 A |
| 160 A |
| 140 A |
| 80 A |
| 80 A |
| 115 A |
| 115 A |
| 115 A |
| 115 A |
| 53 A |
| 97 A |
| 140 A |
| 95 A |
| 115 A |
| 115 A |
| 115 A |
| 115 A |
| 46.5 A |
| 90 A |
| 90 A |
| 90 A |
| 90 A |
| 46.5 A |
Main models:
3RT1054-1AF36 3RT1054-1AP36 3RT1054-1AV36 3 3RT1054-6AF36 RT1054-6AP36 RT1054-6AV36