LV431630 Electric NSX250F 36KA Compact MCCB
Schneider LV431630 250A 3P3D Electric Circuit breaker NSX250F 36KA Compact MCCB
Circuit breaker Compact NSX250F, 36 kA at 415 VAC, TMD trip unit 250 A, 3 poles 3d
NSX Molded Case Circuit Breakers is a full range of high performance molded case circuit breakers (MCCB) in 2 frame sizes designed to meet your needs from thermal-magnetic to advanced Micrologic trip units. This range will soon feature integrated earth leakage protection.
Features:
The ComPact NSX molded case circuit breaker (MCCB) range is designed to optimize space and breaking capacity. The range comes in two frame sizes with a variety of optional functions and accessories.
Specifications:
- Flexible installation: any position; switchboard or wall-mounted
- Nominal current: 16 to 630 A
- 9 Breaking capacities for the 2 sizes of circuit breakers:
- up to 250 A: 25, 36, 50, 70, 100, 150, 200 kA at 415 V
- up to 630 A: 36, 50, 70, 100, 150, 200 kA at 415 V
- both size of circuit breakers with 75 & 100 kA at 690 V - 1, 2, 3 and 4 pole versions available
- Large range of electronic and thermal-magnetic protections
- Advanced trip unit with integrated power metering: I, U, P, E, THD, f, CosPhi
- Interchangeable trip-units to upgrade your panel with smarter functions
- Plug and ready wiring system and communicating accessories
Benefits
Easy and efficient
Two standardized frame sizes for your convenience
Save space, time and effort with integrated earth leakage protection (ELCB), in the molded case circuit breaker (MCCB) frame size
Easy to swap trip units and standardized accessories over time
Wide range of online and offline software tools that help to improve productivity at all stages of your project (Product Selector, EcoStruxure Power Design - Ecodial, EcoStruxure Power Build - Low Voltage, EcoStruxure Power Commission)
Optimize safety
Highly resistant to environmental stresses
Roto-active breaking technology helps to reduce early aging effects and increase operation lifespan
Measure and Communicate
Local and remote communication with trip alarm (earth leakage, overload, short circuit) and pre- alarms (earth leakage) allowing you to proactively increase operational and energy efficiency
Advanced MicroLogic trip unit can assist in providing corrective, preventative and predictive maintenance and energy management to identify potential savings
Working with communication devices, the ComPact NSX inside our Smart Panels becomes an EcoStruxure connected product within our EcoStruxure Power architecture.
Applications
An excellent choice for all standard and specific applications, including:
- Standard applications: industries, buildings, infrastructures
- Specific applications demanding high performance: marine, oil and gas extraction and processing, mining operations, metals and minerals production, and data centers
- Source-changeover systems (TransferPact): service sector (hospital operating rooms, computer rooms, ), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
Technical Dastsheet:
| poles description |
3P
|
|
|---|---|---|
| protected poles description |
3t
|
|
| [In] rated current |
250 A at 40 °C
|
|
| [Ue] rated operational voltage |
690 V AC 50/60 Hz
|
|
| network type |
AC
|
|
| network frequency |
50/60 Hz
|
|
| suitability for isolation |
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2 |
|
| utilisation category |
Category A
|
[Icu] rated ultimate short-circuit breaking capacity
85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
| mechanical durability |
20000 cycles
|
|
|---|---|---|
|
electrical durability 10000 cycles 440 V In conforming to IEC 60947-2 |
|
|
| mounting support |
Backplate
|
|
| upside connection |
Front
|
|
| downside connection |
Front
|
|
| connection pitch |
35 mm
|
| protection type |
L : for overload protection (thermal)
I : for short-circuit protection (magnetic) |
|
|---|---|---|
| trip unit rating |
250 A at 40 °C
|
|
| Long-time pick-up adjustment type Ir (thermal protection) |
Adjustable
|
|
| [Ir] long-time protection pick-up adjustment range |
0.7...1 x In
|
|
| Long-time protection delay adjustment type tr |
Fixed
|
Some models for reference
NSX250F (36 kA 380/415 V)
TM125D LV431623 LV431633 LV431643 LV431653
TM160D LV431622 LV431632 LV431642 LV431652
TM200D LV431621 LV431631 LV431641 LV431651
TM250D LV431620 LV431630 LV431640 LV431650
NSX250N (50 kA 380/415 V)
TM125D LV431833 LV431843 LV431853
TM160D LV431832 LV431842 LV431852
TM200D LV431831 LV431841 LV43 LV431850