2.2KW IGBT Module Ac Motor Vfd Frequency Drive For Three Phase Motor
Three Phase IGBT Module AC Electric Motor Vector Frequency Inverter Speed Control VFD
Features
| Item | Specification | ||
| Standard functions | Maximum frequency | V/F control: 0~500Hz | |
| Carrier frequency | 0.5kHz~16kHz | ||
|
The carrier frequency is automatically |
|||
| Input frequency | Digital setting: 0.01Hz | ||
| Analog setting: maximum frequency x 0.025% | |||
| Control mode | • Voltage/Frequency (V/F) control | ||
| Basic functions | Speed range | 1:50 (VF) | |
| Overload capacity | 60s for 150% of the rated current, 3s for 180% of the rated current | ||
| Torque boost | •Fixed boost | ||
| • Customized boost 0.1%–30.0% | |||
| V/F curve | • Straight-line V/F curve | ||
| • Multi-point V/F curve | |||
|
•N-power V/F curve (1.2-power, 1.4-power, |
|||
| V/F separation | Two types: complete separation; half separation | ||
| Acceleration deceleration curve | •Straight-line ramp | ||
| • S-curve ramp | |||
|
Four groups of acceleration/deceleration time |
|||
| DC braking. | DC braking frequency: 0.00Hz~maximum frequency | ||
| Braking time: 0.0s~36.0s | |||
| Braking action current value: 0.0%–100.0% | |||
| JOG control | JOG frequency range: 0.00–50.00 Hz | ||
| JOG acceleration/deceleration time: 0.0–6500.0s | |||
| Simple PLC and |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
||
| multi-speed operation | |||
| Onboard PID | It realizes process-controlled closed loop control system easily. | ||
| Automatic voltage |
It can keep constant output voltage automatically |
||
| regulation (AVR) | |||
|
Overvoltage |
The current and voltage are limited automatically |
||
| Quick current limiting |
Maximize overcurrent failure and |
||
| Torque limit and control |
It can limit the torque automatically and prevent frequent |
||
| Bus support | Support field bus: Modbus, to realize system integration | ||
| Individualized functions |
Electrify peripheral |
to electrify and to do the security detection of peripheral equipment | |
| Sharing DC bus fuction | to realize several frequency inverters sharing the DC bus | ||
| Timing control | Time range: 0.0–65535.0 minutes | ||
|
Spinning Oscillating |
multi-triangular frequency control function | ||
| Operation | Command source |
Operation panel, control terminal and serial |
|
| Switch in various methods | |||
| Frequency source |
Various frequency sources: digital reference, analog voltage |
||
| Auxiliary frequency source |
10 kinds of auxiliary frequency source. |
||
| 5 digital input terminals, compatible active PNP or NPN input mode | |||
|
2 analog input terminals, among which one only supports voltage |
|||
| Output terminal | 1 digital output terminal | ||
| 1 relay output terminal | |||
|
1 analog output terminal, supporting current outpout |
|||
|
Display and |
LED display | Display the parameter | |
|
Key lock and |
Realize partial or all key lock and define the action range |
||
| Protection function |
Short circuit test of electrified motor, input/output default |
||
| Options |
IO expansion card, differential input PG card, |
||
| Environment | Service site |
Indoor, free from direct sunshine, no dust, corrosive gas, |
|
| Altitude | Less than 1,000m | ||
| Ambient temperature |
-10℃~ +40℃ (Please use the equipment by |
||
| Humidity | Less than 95%RH, no water condensation | ||
| Vibration | Less than 5.9m/s2(0.6g) | ||
| Storage temperature | -20℃~ +60℃ | ||
Application
Shipment and Payment
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.