ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler
The Bacteria Filtration Efficiency (BFE) Tester is developed based on international advanced design concepts and complies with YY 0469-2011, YY/T 0969-2013, and other standards. This instrument is primarily used by metrology verification departments, research institutes, medical mask production units, and related testing facilities to evaluate mask bacterial filtration efficiency performance. It features rapid and accurate measurement capabilities and is equipped with a bioaerosol generator and two Anderson 6-level samplers, meeting the requirements of ASTM F2100, ASTM F2101, EN14683, and other international standards.
The Mask BFE Tester utilizes advanced technology with industrial computer control. Its user-friendly interface and operational methods simplify testing procedures, while test results are displayed directly for convenient and intuitive analysis.
The system operates through an aerosol generating system, aerosol chamber, aerosol transmission device, negative pressure cabinet, and 28.3L/min sampler. The entire detection process is controlled by a console utilizing a microcomputer control system that coordinates and manages the aerosol generation, transmission, negative pressure cabinet, and sampling systems while displaying real-time operational status. All measurement operations are completed automatically.
- Negative pressure test system ensures operator safety
- Integrated measurement system with built-in liquid supply system
- Equipped with dual 6-level Anderson sampling systems (I & II)
- Adjustable peristaltic pump flow rate for specific requirements
- Microbial aerosol generator with adjustable bacterial liquid mist flow and excellent atomization
- PLC + LabView control system with 10-inch high-intensity color touch screen
- USB interface supporting U disk data transfer
- Built-in high-brightness lighting for enhanced observation
- All flow control utilizes mass flow control systems
- Front glass door for convenient experiment monitoring
- YY0469 Mask bacterial filtration efficiency detection standard
- YY/T 0969-2013 Standard for disposable medical masks
- ASTM F2100 medical mask material performance specifications
- ASTM F2101 Standard evaluation method for bacterial filtration efficiency using Staphylococcus aureus bioaerosol
- EN14683 medical mask requirements and test methods
| Parameter | Specification |
|---|---|
| Model | ZL-5065 |
| Vacuum Pump | Oil-free rotary vane vacuum pump, maximum flow up to 57LPM, equipped with silencer; stable airflow |
| Aerosol Generator Flow Control | Mass flow control with accurate regulation |
| I Pneumatic Sampling Flow Rate | Anderson sampling flow rate 28.3L/min, Resolution: 0.1L/min (User calibratable) |
| II Pneumatic Sampling Flow Rate | Anderson sampling flow rate 28.3L/min, Resolution: 0.1L/min (User calibratable) |
| I & II Sampling Channels | Equipped with mass flow controller |
| I Pneumatic Pressure | 0-5kPa |
| II Pneumatic Pressure | 0-5kPa |
| Spray Flowmeter Pressure | 0~120Pa |
| Aerosol Chamber Negative Pressure | Conforms to JJF1190-2008 |
| Working Temperature | 0~50℃ |
| Cabinet Negative Pressure | 0~120Pa |
| Data Storage | Download capability via U disk |
| Mass Flow Controller | 0~20L/min, resolution: 0.1L/min |
| Peristaltic Pump Flow | (0.01~3.0)mL/min |
| High Efficiency Air Filter | Filtration efficiency of particles above 0.3um ≥99.99% |
| Aerosol Generator Quality | Median diameter: Average particle diameter (3.0±0.3)μm, Geometric standard deviation ≤1.5 |
| Anderson Sampler Capture Sizes | Level I: >7μm, Level II: 4.7-7μm, Level III: 3.3-4.7μm, Level IV: 2.1-3.3μm, Level V: 1.1-2.1μm, Level VI: 0.6-1.1μm |
| Aerosol Chamber Specifications | 600mm×80mm×5mm [L×D×T] |
| Positive Quality Control | Sampler particles total: (2200±500)cfu |
| Ventilation Flow | 800m³/min |
| Operating Room Size | L 740×W 940×D 440 mm |
| Dimensions | Approximately L 1200 × W 650 × H 2100 mm |
| Power Supply | AC 220V, 50Hz |
| Instrument Noise | <65dB(A) |
| Weight | 120Kg |
| Power Consumption | <1500W |
| Warranty | 1 year |
- Aerosol generator: 1 set
- Glass mixing chamber: 1 set
- Anderson 6-level biological aerosol sampler: 2 sets
- Sampling pump: 2 sets
- Test tube rack: 1 piece