Screw Compression AC240 CCC 2p 4.5KA Micro Circuit Breaker
Din Rail Mount CCC IECEN60898-1 PA66 Micro Circuit Breaker
- Air temperature: use temperature -30℃~+60℃, storage temperature -40℃~+70℃.
- Altitude: The altitude of the installation site does not exceed 2000 meters, and the altitude of more than 2000 meters should be derated for use.
- Atmospheric conditions: The relative humidity of the air at the installation site does not exceed 50% at +40°C, and the average humidity of the wettest month does not exceed 90% at +20°C.
- Installation category: The installation category is Ⅲ and Ⅲ. Pollution degree: Level 2. Installation method: Use TH35-7.5 standard rail installation.
- Installation conditions: The inclination between the installation surface and the vertical surface should not exceed 5°, and the installation site should be free of significant impact and vibration.
- Wiring method: Use screw compression connection to ensure fast and safe connection of conductors.
| Standard | IEC60898 | |
| Number of poles | 1P,2P,3P,4P | |
| Rated current(In) | 6,10,16,20,25,32,40,50,63 | |
| Rated voltage(Un) | AC240/415V | |
| Rated frequency | 50/60Hz | |
| Tripping curve | B,C,D | |
| Release action characteristics | Time delay | 1.13In>1h Non-trip |
| 1.45In<1h trip | ||
| 2.55In 1s~60S trip | ||
| Instantaneous(Curve C) | 5In >0.1s Non-trip | |
| 10In<0.1s trip | ||
| Magnetic releases operate | B curve:between 3 and 5In | |
| C curve :between 5 and 10In | ||
| D curve: between 10 and 15In | ||
| Ratedbreaking capacit(Lcn) | 6000A | |
| Endurance | >2500 | |
| Circumstance temperature | -5~+40 | |
| Electrical life | >6000times | |
| Mechanical life | 20000 times | |
| Tropical ration | Treatmen 2(RH95%,at 55°C) | |
| Protection degree | IP20 |
Our Micro Circuit Breaker Application:
As general model of mcb,widely used in Household ,building,factory,etc. Working to provide short circuit and overload Protections for sub-main circuits,as well as insulating and connecting functions. Playing roles in lighting,power systerm and other electric equipment as protector, insulator and connector.
Our Micro Circuit Breaker Main technical data
1. Rated current:1,2,3,4,6,10,16,20,25,32,40,50,63A;
2. Tripping characteristics:B(3-5)In,C(5-10)In,D(10-15)In;
3. No. of pole:1P,2P,3P,4P
4. Breaking capacity:4.5KA,6KA;
Packing Detail
1. Product Net weight: 100g/pole
2. Packing quantity& Weight: 12 pole /box, 20 box/carton, 240 pole/carton .
3. N.W: 23KG/carton
4. G.W:24KG/carton
5. Packing Measurement: inner box 22.5×9×8 cm, Carton 45×23.5×33.5 cm ( ie 0.036 cbm)
6. 20 foot container (26 cbm): 19,2000 pole ,800 cartons
7. 40 foot container (54 cbm): 38,4000 pole, 1600 cartons
The Over-Current Protection Property
mcb NBSe
breaker mcb NBSe
circuit breaker mcb NBSe
mini circuit breaker mcb NBSe
MCB Selection
The first characteristic is the overload which is intended to prevent the accidental overloading of the cable in a no fault situation. The speed of the MCB tripping will vary with the degree of the overload. This is usually achieved by the use of a thermal device in the MCB.
The second characteristic is the magnetic fault protection, which is intended to operate when the fault reaches a predetermined level and to trip the MCB within one tenth of a second. The level of this magnetic trip gives the MCB its type characteristic as follows:
| Type | Tripping Current | Operating Time |
| Type B | 3 To 5 time full load current | 0.04 To 13 Sec |
| Type C | 5 To 10 times full load current | 0.04 To 5 Sec |
| Type D | 10 To 20 times full load current | 0.04 To 3 Sec |
· The third characteristic is the short circuit protection, which is intended to protect against heavy faults maybe in thousands of amps caused by short circuit faults.
· The capability of the MCB to operate under these conditions gives its short circuit rating in Kilo amps (KA). In general for consumer units a 6KA fault level is adequate whereas for industrial boards 10KA fault capabilities or above may be required.
Our Services
(1) Warranty ( 24 months warranty )
1. The warranty starts from the delivery date from our factory;
2. During the warranty, any defective product will get repaired or replaced for free ;
3. It is beyond the warranty as the products breaked by the violence , the carelessness or repaired , altered without authorization.
(2) Lead Time
1. Sample orders will be delivered from our factory within 7 working days.
2. General orders will be delivered from our factory within 7-15 working days.
3. Bulk orders will be delivered from our factory within 25 working days at most
(3) Shippment
1. By EMS, DHL, FedEx, TNT, UPS or other express.
2. By our forwarding agent (by air or by sea).
3. By your own forwarding agent.
4. By domestic forwarding agents to any city in China
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

