OMRON H3CR-A8-600 NEW 24-48 VAC 50/60HZ/ 12-48VDC TIMER
Lead time: 3-5 days
New with one year warranty
Time Ranges
Note: When the time setting knob is turned below "0" until the point where the time setting knob stops, the output will
operate instantaneously at all time range settings.
For details, refer to your OMRON website.
Standard (0.05-s to 300-h) Models
| Time unit |
s (sec) |
×10 s (10 sec) |
min (min) |
×10 min (10 min) |
h (hrs) |
×10 h (10 hrs) |
Full scale
setting |
1.2 |
0.05 to 1.2 |
1.2 to 12 |
0.12 to 1.2 |
1.2 to 12 |
0.12 to 1.2 |
1.2 to 12 |
| 3 |
0.3 to 3 |
3 to 30 |
0.3 to 3 |
3 to 30 |
0.3 to 3 |
3 to 30 |
| 12 |
1.2 to 12 |
12 to 120 |
1.2 to 12 |
12 to 120 |
1.2 to 12 |
12 to 120 |
| 30 |
3 to 30 |
30 to 300 |
3 to 30 |
30 to 300 |
3 to 30 |
30 to 300 |
Characteristics
Accuracy of operating
time |
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s) |
| Setting error |
±5% FS ±50 ms *1 |
| Reset time |
Min. power-opening time: 0.1 s max.
Min. pulse width: 0.05 s (H3CR-A/-AS) |
| Reset voltage |
10% max. of rated supply voltage |
| Influence of voltage *2 |
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s) |
| Influence of temperature |
±1% FS max. (±1%±10 ms max. in a range of 1.2 s or 3 s) |
| Insulation resistance |
100 MΩ min. (at 500 VDC) |
| Dielectric strength |
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between current-carrying
metal parts and exposed non-current-carrying metal parts)
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between control output
terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and
operation circuit) for H3CR-AP |
Impulse withstand
voltage |
5 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48
VAC/12 to 48 VDC
5 kV (between current-carrying terminal and exposed non-current-carrying metal
parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and
24 to 48 VAC/VDC |
| Noise immunity |
±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
| Static immunity |
Malfunction: 8 kV
Destruction: 15 kV |
| Vibration resistance |
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours
each
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10
minutes each |
| Shock resistance |
Destruction: 1,000 m/s2 3 times each in 6 directions
Malfunction: 100 m/s2 3 times each in 6 directions |
| Ambient temperature |
Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing) |
| Ambient humidity |
Operating: 35% to 85% |
| Life expectancy *4 |
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h) *3 |
| EMC |
(EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
Immunity Surge: IEC61000-4-5
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Voltage Dip/Interruption: IEC61000-4-11 |
| Case color |
Light gray (Munsell 5Y7/1) |
| Degree of protection |
IP40 (panel surface) |
| Weight |
Approx. 90 g |
Ironman Technology Co.,LTD
About us:
We specializes in automation parts and industrial controls, PLCS,DCS,Module/Board,Power supply,Controller, etc.We maintains an inventory of new and obsolete parts utilized in all areas of the manufacturing and industrial sectors.
Featured Brand:
● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER
● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more !
![]()
We have good price on AB PLC,Omron PLC and Honeywell C200,C300,model number such like TC/TK/MC/CC/511/512/513/514 and some FC series goods,
If you have other enquiry,pls feel free to let me know.