Titanium Plate(Sheet) For Heat Exchanger Medical Titanium Sheet
Standard: ASTM B265
Material: Gr1, Gr11, Gr17
Size: (0.5~1.0) T * (300~1000) W * (800~3000 )L m
Advantage: Quick delivery within 7days if have stock and 15~20days if producing
Payment term: Usually T/T and also L/C, D/A etc can be accepted.
Package: Export cases with five-ply wood box.
Test report: Bao-ti test report can be provided
| Chemical requirements |
| |
N |
C |
H |
Fe |
O |
Al |
V |
Pd |
Mo |
Ni |
Ti |
| Gr1 |
0.03 |
0.08 |
0.015 |
0.20 |
0.18 |
/ |
/ |
/ |
/ |
/ |
bal |
| Gr2 |
0.03 |
0.08 |
0.015 |
0.30 |
0.25 |
/ |
/ |
/ |
/ |
/ |
bal |
| Gr5 |
0.05 |
0.08 |
0.015 |
0.40 |
0.20 |
5.5~6.75 |
3.5~4.5 |
/ |
/ |
/ |
bal |
| Gr7 |
0.03 |
0.08 |
0.015 |
0.30 |
0.25 |
/ |
/ |
0.12~0.25 |
/ |
/ |
bal |
| Gr12 |
0.03 |
0.08 |
0.015 |
0.30 |
0.25 |
/ |
/ |
/ |
0.2~0.4 |
0.6~0.9 |
bal |
| Tensile requirements |
| Grade |
Tensile srength(min) |
Yeild strength(mm) |
Elongation(%) |
| |
KSI |
MPa |
Ksi |
MPa |
|
| 1 |
35 |
240 |
20 |
138 |
24 |
| 2 |
50 |
345 |
40 |
275 |
20 |
| 5 |
130 |
895 |
120 |
828 |
10 |
| 7 |
50 |
345 |
40 |
275 |
20 |
| 12 |
70 |
438 |
50 |
345 |
18 |
![]()