55kW 75HP VFD Variable Frequency Drive with 220V/380V Input, 150% Overload Capacity, and 1:1000 Speed Range
Price:
Please contact quotation
MOQ:
1
Delivery Time:
depends on quantities
Brand:
VEIKONG
Product Description
Performance Features
- Advanced motor control algorithm for precise operation
- High performance open loop vector control
- Optimal V/F mode for enhanced efficiency
- Excellent ramp slope control for smooth acceleration
- Fast auto-tune capability (less than 1 minute)
- Overload capacity: 150% rated output current for 1 minute
- Low frequency torque: 100% rated torque at 0.5Hz, 150% rated torque at 1Hz
Technical Specifications
Input Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 1-phase/3-phase 220V: 200V-240V 3-phase 380V-480V: 380V-480V |
| Allowed Voltage Fluctuation | -15% to +10% |
| Input Frequency | 50Hz / 60Hz, fluctuation less than 5% |
Output Parameters
| Parameter | Specification |
|---|---|
| Output Voltage | 3-phase: 0 to input voltage |
| Overload Capacity | General purpose: 150% rated current for 60s Light load: 120% rated current for 60s |
Control Parameters
| Parameter | V/f Control | SVC | VC |
|---|---|---|---|
| Speed Range | 1:100 | 1:200 | 1:1000 |
| Speed Control Accuracy | ±0.5% | ±0.2% | ±0.02% |
| Frequency Range | 0.00-600.00Hz | 0.00-200.00Hz | 0.00-400.00Hz |
| Startup Torque | 150%/0.5Hz | 180%/0.25Hz | 200%/0Hz |
Product Image
Fault Diagnosis & Troubleshooting
| Fault Name | Code | Possible Causes | Solutions |
|---|---|---|---|
| Inverter Unit Protection | Er. SC | Motor insulation aging, cable damage, output transistor breakdown | Check motor insulation, inspect cables, install reactor or output filter |
| Over Current During Acceleration | Er.OC1 | Output circuit short, acceleration time too short, voltage low | Eliminate external faults, increase acceleration time, adjust voltage |
| Over Current During Deceleration | Er.OC2 | Deceleration time too short, voltage low, braking unit not installed | Increase deceleration time, adjust voltage, install braking unit |
| Over Current at Constant Speed | Er.OC3 | Sudden load added, voltage too low, motor auto-tuning not performed | Remove added load, adjust voltage, perform motor auto-tuning |
| Overvoltage During Acceleration | Er.OU1 | Input voltage too high, acceleration time too short | Reduce power supply voltage, increase acceleration time |
| Low Voltage | Er.Lv1 | Instantaneous power failure, input voltage out of range | Check input power supply, adjust voltage to normal range |
| Frequency Inverter Overload | Er. oL | Load too large, acceleration time too short | Reduce load, increase acceleration/deceleration time |
| Motor Overload | Er.oL1 | Motor blocked, large inertia load, improper parameter settings | Check motor and mechanical conditions, adjust parameter settings |
Compatibility & Applications
This 55kW VFD is designed to replace famous brand variable frequency drives in general industrial applications, providing reliable motor control with multiple operation modes and comprehensive protection features.
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen LuoX Electric Co., Ltd.
Location
No.87, Youth Pioneer Park, Beijing
Contact Person
Terry