5.5kW-15kW VFD Load Reactor AC Line Choke with F/H Class Insulation for 380V-1140V Systems
Price:
Negotiable
MOQ:
1
Delivery Time:
3 days, depend on the order quantity
Brand:
VEIKONG
Product Description
AC Line Choke Load Reactor for Variable Frequency Drives
High-performance AC choke output reactor designed for 5.5kW, 7.5kW, 11kW, and 15kW AC drives, featuring F/H class insulation for superior thermal performance and reliability.
Primary Function
This filter reactor is engineered for low-voltage filter cabinets, connected in series with filter capacitors to create tuned resonance circuits that effectively absorb harmonic currents from power grids. It addresses harmonic pollution generated by rectifiers, converters, and frequency converters, protecting main transformers and electrical equipment while improving system power factor.
Key Performance Benefits
- Reduces harmonic interference and waveform distortion from frequency converters and DC speed regulators
- Enhances frequency converter resistance to voltage unbalance exceeding 1.8% of rated voltage
- Protects rectifier modules and components from peak capacitive currents when power supply capacity exceeds inverter capacity by 5 times
- Improves power supply power factor and reduces harmonic current content
- Minimizes current and voltage waveform distortion rates for improved power quality
Technical Specifications
| Parameter | Specification |
|---|---|
| Rated Operating Power | 380V / 690V / 1140V |
| Operating Frequency | 50/60Hz |
| Current Range | 5-1600A |
| Operating Temperature | -25℃ to 50℃ |
| Dielectric Strength | Core-winding, AC 3000V/50Hz/5mA, no damage in 60s |
| Insulation Resistance | Core-winding, DC 1000V, Resistance >100M ohm |
| Noise Level | Less than 65dB (measured 10 meters horizontally) |
| Protection Class | IP00 |
| Insulation Class | F/H |
| Compliance Standards | GB 19212.1-2008, GB/T1094.6-2011 |
Product Images
Recommended Applications
- Multiple frequency converters operating in parallel close connection
- Power supply lines experiencing significant disturbance from other equipment
- Phase voltage imbalance exceeding 1.8% of rated voltage
- Installations with numerous converters on the same power line
- Systems with power factor correction devices to reduce cos C overload
- Power supply capacity of 60kVA or higher with frequency converters within 10 meters of large capacity power sources
- Frequency converters powered by very low impedance lines (10 times higher than inverter's rated value)