IEC 60811-1-4 Compliant Low Temperature Impact Test Apparatus with 100 mm Drop Height and Single or Three Station Configuration
Price:
Negotiatable
MOQ:
1 Set
Delivery Time:
15 days
Brand:
HeJin
Product Description
IEC 60811-1-4 Low Temperature Impact Test Apparatus (100 mm Drop Height)
The IEC 60811-1-4 Low Temperature Impact Test Apparatus evaluates the impact resistance of electrical cables, insulation, and sheath materials under low-temperature conditions. Compliant with IEC 60811-1-4 standard requirements, this device is widely used by cable manufacturers, third-party testing laboratories, and quality control departments to verify material performance in cold environments.
When used together with a low-temperature chamber, the apparatus delivers reliable, repeatable impact testing results, ensuring products meet international safety and durability standards.
Applicable Standards
- IEC 60811-1-4 – Common test methods for insulating and sheathing materials of electric cables – Low temperature test
- IEC 60884-1 – Plugs and socket-outlets for household and similar purposes (relevant clauses)
Key Features
- Designed in strict accordance with IEC 60811-1-4 requirements
- Used inside a low-temperature chamber for accurate environmental simulation
- Impact device placed on a 40 mm thick rubber pad during testing
- Simple, durable manual mechanical release structure
- Available in single-station or three-station configurations for higher testing efficiency
Technical Parameters
| Model | Impact test apparatus HC9924 | Impact test apparatus HC9924A |
|---|---|---|
| Station | Single station | Three stations |
| Weight of the impact hammer (g) | 1000±2 and 100±1 | 100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500 (See table 1 and 2) |
| Height of the impact (mm) | 100 | 100 |
| Steel intermediate piece | Φ20, bottom end rounded R300, 100g | Φ20, bottom end rounded R300, 100g |
| Standard | IEC60884-1 24.4 Figure 27 IEC60884-1 30.4 Figure 42 | IEC60811-1-4 |
| Operation | Manual, mechanical release | Manual, mechanical release |
Table 1: Hammer Mass for Power Cables (Fixed Installation)
| Overall diameter (mm) Above | Overall diameter (mm) Up to and including | Mass of hammer (g) |
|---|---|---|
| - | 4.0 | 100 |
| 4.0 | 6.0 | 200 |
| 6.0 | 9.0 | 300 |
| 9.0 | 12.5 | 400 |
| 12.5 | 20.0 | 500 |
| 20.0 | 30.0 | 750 |
| 30.0 | 50.0 | 1000 |
| 50.0 | 75.0 | 1250 |
| 75.0 | - | 1500 |
Table 2: Hammer Mass for Flexible Cables and Telecommunication Cables
| Overall diameter (mm) Above | Overall diameter (mm) Up to and including | Mass of hammer (g) |
|---|---|---|
| For flat cords | - | 100 |
| - | 6.0 | 100 |
| 6.0 | 10.0 | 200 |
| 10.0 | 15.0 | 300 |
| 15.0 | 25.0 | 400 |
| 25.0 | 35.0 | 500 |
| 35.0 | - | 600 |
Product Structure Diagram
Why Choose This Low Temperature Impact Test Apparatus?
With a robust mechanical design, strict standard compliance, and flexible configuration options, this IEC 60811-1-4 impact tester provides accurate, repeatable, and internationally recognized test results, helping manufacturers ensure product reliability and regulatory compliance before market entry.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Location
No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Contact Person
Tessa Huang