HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
                                                                                                           
Verified Supplier
14 Years
Since 2012
Menu
Machinery Refrigeration & Heat Exchange Equipment Other Refrigeration & Heat Exchange Equipment

270pcs/Hour Vacuum Chamber Leak Test For Air Conditioning Condenser

Price Negotiable
Price: Negotiatable
MOQ: 1 Set
Delivery Time: 90 days
Brand: HeJin
Product Description

Leak Testing Equipment For Air-Conditioning Condenser / Evaporator Vacuum Chamber Method

 

product information:

The vacuum chamber helium leak detection system has three vacuum chambers, and three vacuum chambers work linked. The operator puts the parts into the vacuum chamber and connects them with the quick joints, and then simultaneously presses the two green buttons on the upper edge of the vacuum chamber. The chamber door is closed and the detection cycle begins automatically. Grating protectors are installed on both sides of the vacuum chamber door, and when the door is closed, it is ensured that there is no object in the door area that interferes with the movement of the door. Once one of the doors is closed, the detection cycle in this chamber begins. Leak Testing Equipment

 

Parameter: (can be customized according to client's requirements)

Workpiece

Air conditioning condenser / evaporator

Vacuum chamber size L1250mmX W480mmX D300mm
Vacuum chambers 3 pieces (2 pieces per chamber)
Fixture 6 sets. Leak Testing Equipment
Gas for gross leak detection 2.5 Mpa (downward adjustable)
Tracer gas Helium
Reject point 2g/year
Tracer gas pressure 2.5 Mpa (downward adjustable)
Production capacity 270 pcs/hour
Helium recovery Recovery rate ≥95%
Vacuuming time 50s
Helium filling and detection time 10s
Helium recovery time 8s
Workpiece loading and unloading Manual

 

System Configuration:

No. Item Brand
1 Chamber and fixture HJ
2 Chamber door and auto- closing mechanism HJ
3 Helium-filled and recovery connector HJ
4 Vacuum pump BAOSI
5 Vacuum gauge Agilent
6 Leak detector Agilent
7 Pressure sensor JUMO etc.
8 Electromagnetic valve AIRTAC, SMC etc.
9 High pressure valve GSR, ASCO etc.
10 Standard leak HJ
11 Helium boosting system HJ
12 PLC OMRON
13 Touch screen Weinview
14 Electrical parts FUJI, Schneider etc.
15 Pipes and fittings Made in china
16 Helium concentration detector HJ

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Location No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Contact Person Tessa Huang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.