Changsha Xingheda Technology Co., Ltd
                                                                                                           
Verified Supplier
10 Years
Since 2016
Menu

ELTEK Flatpack S HE 48V/1000W 241122.105 Rectifier Module

Price Negotiable
Price: Negotiable
MOQ: 1pc
Delivery Time: 3-7 work days
Brand: ELTEK
Product Description

        ELTEK Flatpack S HE 48V/1000W 241122.105 rectifier module

   

        Product Description:

ELTEK Flatpack S HE 48V/1000W rectifier module is used in the 1U high, 2 or 3 rectifier positions power rack with Smartpack S controller and battery and load distributions, the Flatpack S rectifiers cover 2 to 5.4kW applications using a minimum of space, less than 6 liters, and low heat dissipation.

Model 48/1000 HE 48/1800 HE
Part number 241122.105 241122.125
INPUT DATA
Voltage (nominal) 185 - 250 VAC / 185 - 250 VDC 1) 195 - 277 VAC / 195 - 250 VDC 1)
Voltage (operating range) 85 - 300 VAC / 85 - 250 VDC 1) 85 - 305 VAC / 85 - 250 VDC 1)
Current (maximum) @ nominal input, full load 5.9 ARMS 9.9 ARMS
Frequency 45 - 66 Hz / 15 - 18.5 Hz2) / 0 Hz1) 45 - 66 Hz / 0 Hz1)
Power Factor > 0.99 at 50% load or more
Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range
OUTPUT DATA
Voltage (default) 53.5 VDC
Voltage (adjustable range) 43.5 - 57.6 VDC
Power (maximum) @ nominal input 1000 W 1800 W
Power @ 85 VAC 420 W 700 W2)
Current (maximum) @ nominal input 20.9 A (@VOUT < 48VDC) 37.5 A (@VOUT < 48VDC)
Hold up time, maximum output power >20ms; output voltage > 41 VDC >10ms; output voltage > 42 VDC
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple < 150 mVPP , 30 MHz bandwidth
Protection ORing FET, Short circuit proof, High temperature protection, Over voltage Shutdown
OTHER SPECIFICATIONS
Efficiency 95.5 % 96 %
Isolation 4.0 kVDC - input to output, 2.5 kVDC - input to earth, 710 VDC - output to earth 5.0 kVDC - input to output, 2.5 kVDC - input to earth, 710 VDC - output to earth

 

Alarms: Red LED

Low / high input voltage shutdown, High / low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure
Warnings: Yellow LED Rectifier in power de-rate mode, Remote output current limit activated, Input voltage out of range, flashing at overvoltage, Loss of CAN communication with controller
Normal operation: Green LED
MTBF (Telcordia SR-332 Iss.I method III (a)) >315 000 (@ Tambient : 25 °C) >300 000 (@ Tambient : 25 °C)
Operating temp. (5-95% RH n.cond. hum.) -40 to + 85°C [-40 to +185°F] -40 to + 85°C [-40 to +185°F]
Max output power de-rates above temp / to 45°C [113°F] / 600W @ 85°C[185°F] 55°C [113°F] / 1000W @ 85°C[185°F]
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Altitude 2000m (~6500ft) 4000m (~13000ft)
Dimensions[WxHxD] / Weight 72 x 41.5 x 217mm (2.83 x 1.63 x 8.54”) / < 850 g (1.9 lbs)
DESIGN STANDARDS
Electrical safety

EN 62368-1:2020+A11:2020, IEC 62368-1:2018, UL 62368-1:2019

IEC 60950-1:2013

 

EMC

EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019

IEC 61000-6-5:2015+Cor1:2017, EN 50121 -4:2016/A1:2019, -5:2017/A1:2019 ETSI EN 300 386 V.2.1.1, FCC CFR47 part 15B:2020 (parts of)

Marine DNVGL-CG-03393)

 

Environment

ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised

EU 2015/863 (RoHS), 2012/19/EU (WEEE), IEC 63000:2018

 

 

 

 

 

 

 

 

 

 

 

Product Details:


If you are interested, please let us know the specific model. We will provide the best service and the best price!
 

 

Pr

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Xingheda Technology Co., Ltd
Location 2506 Xidi Building, No. 8 Fenglin Third Road, Yuelu District, Changsha City, Hunan Province
Contact Person Amy Lee

Request A Quote

Please check your email address.
Your message must be at least 20 characters.