ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module
ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module
Product Description:
ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module is used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.
| Model | 24/1000 HE |
| Part number | 241122.205 |
| INPUT DATA | |
| Voltage (nominal range) | 185 VAC/DC - 305 VAC / 300VDC |
| Voltage (operating range) | 85 VAC/DC - 305 VAC / 300VDC |
| Frequency (nominal / range) | 45 - 66 Hz / DC |
| Maximum current | 5.9 ARMS |
| Power Factor | > 0.99 at 50% load or more |
| Protection |
Fuse Shutdown above 305 VAC / 300 VDC |
| OUTPUT DATA | |
| Voltage (default) | 26.7 VDC |
| Voltage (adjustable range) |
21 - 29 VD 1) C |
| Max power, nominal input | 1000 W |
| Max power, @ 85 VAC/DC | 440 W |
| Max current | 41.7 A (@VOUT < 24 VDC) |
| Current sharing | ±5% of maximum current from 10 to 100% load |
| Static voltage regulation (10-100% load) | ±0.5% |
| Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
| Hold up time | >20ms; output voltage > 21 VDC |
| Ripple | < 150 mVPP , 30 MHz bandwidth |
|
Protection |
Blocking OR-ing Diode, Short circuit proof, Over voltage protection and High temperature protection |
| OTHER SPECIFICATIONS | |
| Peak Efficiency | 92.5 % |
| Isolation | 3.0 kVAC - input and output, 1.5 kVAC - input earth, 0.5 kVDC - output earth |
| Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
| Warnings (Yellow LED) | Rectifier in power de-rate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
| Normal (Green LED) | Input and output ok |
| Potential alarm relay (normally closed) | Opens on alarms and mains outage |
| MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1) | >1 975 044 (@ Tambient : 25 °C) |
| Operating temperature (5 - 95% RH non-cond.) | - 40 - 85°C [-40 - 185°F ] |
| Max output power de-rates above temp / to | 45°C [+113°F] / 400 W |
| Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
| Dimensions[WxHxD] / Weight | 72 x 41.5 x 217mm (2.83 x 1.63 x 8.54”) / < 850 g (1.9 lbs) |
| DESIGN STANDARDS | |
| Electrical safety |
EN 62368-1:2020+A11:2020, IEC 62368-1:2018, UL 62368-1:2019 IEC 60950-1:2013 |
|
EMC |
EN 61000-6-1:2019, -6-2:2019, -6-3:2007 + A1:2011, -6-4:2019 IEC 61000-6-5:2015, FCC CFR 47 Part 15:2013 ETSI EN 300 386v2.2.0, EN50121-4:2016 + A1:2019, -5:2017 + A1:2019 |
| Marine | DNVGL-CG-0339, ABS PDA Certificate2) |
|
Environment |
ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS), 2012/19/EU (WEEE), IEC 63000:2018 Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |