ELTEK Flatpack S 24V/1000W SIL3 OVP 241122.290 Rectifier Module
ELTEK Flatpack S 24V/1000W SIL3 OVP 241122.290 rectifier module
Product Description:
ELTEK Flatpack S 36V/1000W HE UI 241122.235 rectifier module is used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.
| Model | 24/ 1000 SIL3 OVP |
| Part number | 241122.290 |
| INPUT DATA | |
| Voltage (nominal) | 230 V AC/ DC |
| Voltage (full power) | 185 - 275 V AC/ DC |
| Voltage (full power, reduced power factor) | 275 - 305 V AC/ DC |
| Voltage (reduced power, linear de-rating) | 85 - 185 V AC/ DC |
| Frequency (nominal / range) | 45 - 66 Hz / 0 Hz |
| Current (maximum) | 5.9 A RMS |
| Power Factor | > 0.99 at 50% load or more |
| Protection | Fuse and Shutdown above 305 V AC / 300 V DC and below 85V AC/ DC |
| OUTPUT DATA | |
| Voltage (default) | 26.7 V DC |
| Voltage (adjustable range) | 21.5 - 28 V DC |
| Power (maximum) @ nominal input | 1000 W |
| Power @ 85 VAC | 420 W |
| Current (maximum) @ nominal input | 41.7 A (@V OUT < 24 VDC) |
| Current sharing (10 - 100% load) | ±5% of maximum current from 10 to 100% load |
| Static Voltage regulation (10 - 100% load) | ±0.5% |
| Dynamic Voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
| Hold up time | >20ms; output voltage > 41 V DC |
| Ripple | < 200 mV peak to peak, 30 MHz bandwidth |
| Protection | Blocking OR-ing Diode, Short circuit proof and High temperature protection |
| Overvoltage protection, SIL3 parameters |
• Protection level: 30V • PFD = TBS • Proof test interval: 15 years • SFF = TBS • Handles dual component failure |
| OTHER SPECIFICATIONS | |
| Efficiency @ nominal input | 92.50 % |
| Isolation | 3.0 kVAC - input to output, 1.5 kV AC - input to earth & 0.5 kV DC - output to earth |
| Alarms: Red LED |
Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
| Warnings: Yellow LED |
Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
| Normal operation: Green LED | |
| Potential alarm relay (normally open) |
Opens on alarms, mains outage and >40% loaded (ensures redundancy in 1+1 system) when not connected to a controller |
| Normal (module running): Green LED 'on' | |
| Acoustic noise | < 46dBA at nominal input and full load |
| MTBF (Telcordia SR-332 Issue I method III (a)) | >300 000 (@ Tambient : 25 °C) |
| Operating temperature |
-40 to +85°C ( -40 to +185°F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 1000W @ 45°C (113°F) to 400W @ 85°C(185°F) |
| Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
| Dimensions[WxHxD] / Weight | 72 x 41.5 x 210mm (2.83 x 1.63 x 8.27”) / < 1 kg (2 lbs) |
| DESIGN STANDARDS | |
| Electrical safety | UL 60950-1, EN 60950-1, IEC 61508 |
| Marine | DNV-OS-D202, Ch.2 Sec.4 (DNV2.4): Temperature Cl.B, Humidity Cl.B, Vibration Cl.A, EMC Cl.B1) IEC 60945-4th edition |
| EMC |
ETSI EN 300 386 V.1.4.1 EN 61000-6-1 / -2 / -3 / -4 / -5 FCC Part 15 Subpart 109 |
| Environment |
ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) RoHS (2011/ 65/ EU) and WEEE (2002/96/ EC) compliant |
Product Details:
If you are interested, please let us know the specific model. We will provide the best service and the best price!
Pr
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.