12V/24V DC Diesel Pump:50L/min,IP55,Metering Nozzle,for Farms/Sites/Fleets
| Parameter Category | Specific Specification |
|---|---|
| Model | Generic 12V/24V DC Self-Priming Diesel Electric Fuel Transfer Pump (specialized for diesel/kerosene transfer) |
| Product Type | DC-powered self-priming fuel transfer pump with IP55 protection, cast iron durability, and metering nozzle precision |
| Electrical Parameters |
|
| Flow & Head Performance |
|
| Structural & Material Details |
|
| Test Item | Test Condition | Test Result |
|---|---|---|
| Flow Stability & Metering Accuracy | Operate at 12V/24V (50L/min) for 2 hours | Flow remains 50±1 L/min; metering accuracy ±0.5L |
| IP55 Protection | Expose to dust (8h) + water jets (10min) | No dust/water ingress; normal operation |
| Self-Priming & Suction | Test suction from 3m depth with diesel | Self-primes in 9 seconds; residual fuel 1.8L |
| Durability | 50 continuous 1-hour cycles with kerosene | No wear on cast iron parts; nozzle retains accuracy |
- Dual-Voltage Operation: Compatible with both 12V and 24V systems
- IP55 Protection: Weather-resistant for outdoor use in harsh environments
- Rugged Cast Iron Construction: Durable and long-lasting with 8+ year service life
- Precision Metering Nozzle: Tracks fuel volume and auto-shuts off when full
- Complete Accessory Kit: Includes 2m suction hose and 4m delivery hose
Ideal for farms with mixed 12V and 24V equipment. The metering nozzle enables precise fuel tracking for cost control, while the portable design suits field operations.
Fast 50L/min flow rate keeps heavy machinery operational with minimal downtime. IP55 rating withstands dust and rain common on job sites.
Efficient solution for delivery companies needing to refuel multiple vehicles quickly. Metering data helps optimize fuel consumption across the fleet.
Yes. Use a 10L known-volume container to check and adjust the calibration screw until accuracy is ±0.5L.
Gasoline vapors are explosive and degrade cast iron seals. Use only with diesel or kerosene - gasoline use voids warranty.
1. Clean nozzle/filter; 2. Check for kinked hoses; 3. Ensure battery is fully charged.
1. Drain residual fuel; 2. Clean nozzle/hoses; 3. Coat cast iron with anti-rust oil; 4. Store in dry area above 0℃.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.