HESS 16S18P 48V 100Ah Lithium Battery Pack With 5KW Inverter
5KWh 48V 100Ah Lithium Battery Pack For Home Energy Storage System Equiped With 5KW Inverter
48V 100Ah 5KWh LiFePo4 Battery and5KW inverter Specification
| Battery parameters | Item | Cell | Battery pack |
| Parameter | 3.2V 6Ah | 51.2V 100Ah | |
| Quantity | 288 | 1 | |
|
System capacity
|
5kWh (can be parallel to 10KWh) | ||
| Overall system efficiency | 90%±5% | ||
| DOD | 80% | ||
| Actual available capacity | ≥4.6kWh | ||
| Cycle life | Over 4000 cycles(0.3C cycle, 25℃(capacity retention 80%) | ||
| Continuous charging current(A) | 20A(adjustable) | ||
| Continuous discharge current(A) | 40A (adjustable) | ||
| Full power charge and discharge rate | 0.3 C | ||
| energy capacity of battery | 25°C 4kWh (100% DOD @ 1C rate) | ||
| - 20°C 3.6 kWh(100% DOD @ 1C rate) | |||
| Storage temperature | < 45°C is the best storage temperature | ||
| Self-discharge | 25°C,≤5% per month | ||
| IP rating of enclosure | IP55 | ||
| Inverter Specification | |||
| Model | 5.5kW | ||
| Parameters | Continuous power:5.5(KW) Peak power:11(KW)5S | ||
| Nominal rated voltage:(Vdc)51.2 (Lithium iron) | |||
| Charging current:(A)0~80(adjustable) | |||
| Cut-off voltage:(V)58.4 | |||
| Maximum discharge current:(A)100(adjustable) | |||
| Grid voltage range: 230VAC±5% Input maximum current:100A Frequency:50Hz | |||
| Inverter voltage range:230Vac±5%(Inverter mode) Frequency:50/60Hz±1%(Automatic detection) Output waveform:Pure sine wave Efficiency:>90%(88%resistive load) Protection function:Over voltage and under voltage protection, overload protection, short circuit protection, over temperature protection. | |||
Battery pack interface
Working principle
Installation Location:
Consider the below points before selecting installation location:
1 There are no flammable or explosive materials
2. The floor is flat and level.
3 Install the system in a visible location so that user can read the LCD display parameter at any time.
4 The area is completely waterproof
5 Make sure there is 20 cm distance from the two side, 50 cm distance from bottom of the unit.
6 The ambient temperature is within the range from 0°C to 55°C.
7 The temperature and humidity are maintained at a constant level.
8 The installation areas shall avoid of direct sunlight
9 The distance from air outlet of inverter is more than 0.5 meters.
10 The distance from heat source is more than 2 meters.
11 There is minimal dust and dirt in the area.
Get in Touch