TA-201E Total Organic Carbon Analyzer with 0-30000mg/L Range and 680-1200℃ Combustion Temperature
Price:
$100.00--120/set
MOQ:
1
Delivery Time:
3-7 days
Brand:
HiYi
Product Description
Product Overview
The TA-201E Total Organic Carbon Analyzer employs high-temperature catalytic combustion oxidation methodology. Samples are introduced into high-temperature combustion tubes and low-temperature reaction tubes with purified oxygen gas. Organic and inorganic carbon compounds are converted to carbon dioxide through catalytic oxidation, with inorganic carbon decomposed via acidification. The resulting CO₂ is transported via carrier gas to a non-dispersive infrared gas detector (NDIR) for precise measurement of total carbon (TC) and inorganic carbon (IC). Total organic carbon (TOC) is calculated as TOC = TC - IC.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measurement Range | 0-1000mg/L (non-dilution), up to 30000mg/L with dilution |
| Repeatability | ≤ 3% |
| Lower Detection Limit | 0.5mg/L |
| Analysis Time | 2-4 minutes |
| Injection Volume | 10μL-500μL |
| Power Supply | AC 220V ±10% 50/60Hz |
| Power Consumption | 1000W during furnace heating |
| Combustion Temperature | 680℃-1200℃ |
Key Features & Benefits
- High-temperature catalytic oxidation effectively processes difficult-to-digest organic carbon for high-concentration TOC sample analysis
- Rapid analysis cycle of 1-4 minutes per measurement
- Enhanced safety with multiple protection systems and independent overheating protection circuits
- Real-time flow monitoring ensures measurement stability and data reliability
- Comprehensive pipeline cleaning and purging capabilities reduce maintenance time
- Automated waste discharge and acid feeding with stable reagent control
- Minimal consumable usage: 0.5μL high-purity water, 2ml acid reagent, 2000ml high-purity oxygen per measurement
- High-precision NDIR CO₂ detection with excellent linearity (R²≥99.9%)
- 680℃ combustion temperature extends catalyst and combustion tube lifespan, especially for salt-containing water samples
- User-friendly 7-inch touch screen interface with intelligent operating system
Operating Requirements
Environmental Conditions
Ambient temperature: 0-40℃, Relative humidity: 10-85%, Indoor placement only
Installation Requirements
Minimum 20cm clearance around instrument for proper heat dissipation, no stacking on top
Required Consumables
High-purity oxygen (≥99.999%), Carbon dioxide-free water (TOC≤0.5mg/L), 10% phosphoric acid reagent