Fixed Type Vacuum VCB Circuit Breaker With Environmental Protection
MOQ:
1
Delivery Time:
15 working days
Brand:
KNKONG
Product Description
Fixed type 205mm phase spacing vacuum circuit breaker with environmental protection
Voltage: 12KV-24KV
Current: 630A-2000A
Breaking current: 20KA-25KA
Type: Fixed
Product overview
"High-voltage vacuum circuit breaker" is named because its arc extinguishing medium and the insulating medium in the contact gap after arc extinguishing are both vacuum; vacuum circuit breakers are small in size, light in weight, suitable for frequent operation, and arc extinguishing without maintenance. Advantages, it is more popular in the distribution network.
Vacuum circuit breakers can usually be divided into multiple voltage levels. The low-voltage type is generally used for explosion-proof electrical applications. Like coal mines and so on.
Technical Parameters
| No. | Item | Unit | Parameter | ||||||
| 1 | Rated voltage | KV | 12 | ||||||
| 2 | Rated frequency | Hz | 50/60 | ||||||
| 3 |
Rated insulation level |
1min power frequency withstand voltage(r. m. s) |
KV |
42(phase-to-phase, phase-to-earth) 48(across the isolating distance) |
|||||
| Lighting impulse withstand voltage (peak) |
75(phase-to-phase, phase-to-earth) 85(across the isolating distance) |
||||||||
|
4 |
Rated current |
A |
630 | 630 | 1250 | 1600 | |||
| 1250 | 1250 | 1600 | 2000 | ||||||
| 2000 | 2500 | ||||||||
| 2500 | 3150 | ||||||||
| 4000 | |||||||||
| 5 | Rated short-circuit breaking current |
KA |
20 | 25 | 31.5 | 40 | |||
| 6 | Rated short-time withstand current | 20 | 25 | 31.5 | 40 | ||||
| 7 | Rated short-circuit marking current | 50 | 63 | 80 | 100 | ||||
| 8 | Rated peak withstand current | 50 | 63 | 80 | 100 | ||||
| 9 | Rated duration of short-circuit | s | 4 | ||||||
| 10 | Rated operating sequence | O-0.3s-O/C-180s-O/C | |||||||
| 11 | Breaking times of rated short-circuit current | Times | 30/20 times(40KA) | ||||||
| 12 | Mechanical endurance | Ops | 20000 | ||||||
| 13 | Rated single capacitor bank breaking current |
A |
630 | ||||||
| 14 | Rated back-to-back capacitor bank breaking current | 400 | |||||||
| 15 | Double-earth fault breaking current | 27.4 | |||||||
| 16 | Allowable maximum contact erosion |
mm |
3 | ||||||
| 17 | Clearance between open contacts | 10±1 | |||||||
| 18 | Over stroke | 3.5±0.5 | |||||||
| 19 | Non-simultaneity of 3-phase opening and closing |
ms
|
≤2 | ||||||
| 20 | Bounce duration of contact closing | ≤2 | |||||||
| 21 | Average breaking speed (instant breaking 6mm) |
m/s
|
1.1±0.2 | ||||||
| 22 | Average making speed | 0.8±0.2 | |||||||
| 23 | Making time |
ms
|
≤100 | ||||||
| 24 | Breaking time | ≤50 | |||||||
|
25 |
Resistance of each phase main circuit |
μ Ω |
630A | ≤50 | |||||
| 1250A | ≤45 | ||||||||
| 1600A~2000A | ≤35 | ||||||||
| ≥2500A | ≤25 | ||||||||
| 26 | Contact breaking bounce amplitude | mm | ≤2 | ||||||
|
27 |
Rated operating voltage | Rated operating voltage(V)AC/DC |
V |
24* | 110 | 220 | |||
| Scope of normal operation voltage | Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed | ||||||||
| 28 | Rated voltage of energy storage motor | V | AC110/220,DC110/220 | ||||||
| 29 | Energy storage time | S | ≤15 | ||||||