55KW 3 Phase Pump Starter 480VAC Electric Motor Starter 3 Phase
55kw 3phase 400V Built In Bypass Soft Starter For Pump
EM motor soft starter is suitable for squirrel cage asynchronous motor control with various loads to ensure reliable start of motor. It has a complete system protection function, extend the service life of the system, reduces the cost of the system, improves the reliability of the system and compatible with various functions of all devices. It is a new ideal alternative for traditional star triangle starter and self-coupling decompression starter.
- Effectively reduce the starting current of the motor; Can reduce the distribution capacity, avoid grid expansion investment.
- Reduce the starting stress of motor and load equipment; Prolong the service life of the motor and related equipments.
- Soft stopping function can effectively solve the parking surge problem of inertial systems; That is a traditional starting equipment cannot be achieved.
Porducts Feature:
Advanced software performance
With intelligent logic, fast complete soft starting process. Parameter can directly calibrate current and voltage displaying value.
Excellent control performance
With voltage and current limiting and etc six starting modes to adapt to different types of load; and soft stop mode to reduce power shock.
Perfect protection function
All series with over current, over voltage, overlaod and etc protection functions ,it can effectively guarantee the normal operation of the motor.
Stable communication control
Optional RS485 communication module, support MODBUS communication protocol, realize network communication with upper computer, facilitate user remote debugging and control.
More product certification
Products with ISO9001, 3C, CE and other quality system certification to meet customer equipment export requirements.
Model
|
Model |
Rated Power |
Rated Current |
Dimensions(mm) |
N.W. |
||||
|---|---|---|---|---|---|---|---|---|
|
(KW) |
(A) |
A |
B |
C |
D |
E |
(Kg) |
|
| EM-GB3-011 | 11 | 22 | 152 | 92 | 312 | 269 | 215 | 5.2 |
| EM-GB3-015 | 15 | 30 | ||||||
| EM-GB3-018 | 18.5 | 37 | ||||||
| EM-GB3-022 | 22 | 44 | ||||||
| EM-GB3-030 | 30 | 60 | ||||||
| EM-GB3-037 | 37 | 75 | 152 | 92 | 312 | 269 | 215 | 5.2 |
| EM-GB3-045 | 45 | 90 | ||||||
| EM-GB3-055 | 55 | 110 | ||||||
| EM-GB3-075 | 75 | 150 | 275 | 160 | 410 | 390 | 265 | 18.3 |
| EM-GB3-090 | 90 | 180 | ||||||
| EM-GB3-115 | 115 | 230 | ||||||
| EM-GB3-132 | 132 | 264 | 443 |
320 160*2 |
600 | 540 | 290 | 35.8 |
| EM-GB3-160 | 160 | 320 | ||||||
| EM-GB3-200 | 200 | 400 | ||||||
| EM-GB3-250 | 250 | 500 | ||||||
| EM-GB3-280 | 280 | 560 | ||||||
| EM-GB3-315 | 315 | 630 | ||||||
| EM-GB3-355 | 355 | 710 | ||||||

Technical Specifications
| Selectable soft starting profiles | Customisable protection | |
|
Adaptive Control Constant Current Current Ramp |
Motor overload Excess Start Time Undercurrent Instantaneous overcurrent Current imbalance |
Mains frequency Input Trip Motor thermistor Power circuit Phase sequence |
| Selectable soft stopping profiles | Models for all connection requirements | |
|
Coast To Stop Timed voltage ramp soft stop Adaptive Control Brake |
23 A~1000 A (nominal) 380~415 VAC Internally bypassed In-line or inside delta connection |
|
| Extensive input and output options | Optional features for advanced applications | |
|
Remote control inputs (3 fixed, 2 programmable Relay outputs (1 fixed, 3 programmable) Analog output Built-in PT100 RTD input Optional expansion cards |
Input/output expansion RTD and Ground fault protection Communication modules: Modbus, Modbus RTU |
|
| Easy-to-read display with comprehensive feedback | ||
|
Removable keypad Multi-language feedback Date and time stamped event logging Operational counters (number of starts, hours-run, kWh) Performance monitoring (current, voltage, power factor, kWh) User-programmable monitoring screen |
||
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.